A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility and safety of a transvenous lead extraction program implementation in South America: Challenges, early outcomes, and global collaboration-A single-center experience. | LitMetric

Background: Transvenous lead extraction is the standard of care for cardiac implantable electronic device (CIED) malfunction/infection-related removal. However, data on its performance and results in underdeveloped countries are limited.

Objective: The purpose of this study was to report the feasibility and efficacy of a lead extraction program in a tertiary hospital in Chile, South America.

Methods: Patients requiring CIED removal at the Electrophysiology Division of the Hospital las Higuera's were retrospectively analyzed. Outcomes including procedure-related mortality, procedural success and failure, and cardiac and vascular complications were reported.

Results: A total of 15 patients were analyzed (median age 68 [interquartile range 52-75] years; 80% male). Patients with lead extraction difficulty index >10 represented 33% of patients. Infection was the indication for removal in all patients, with pocket infection (80%). Mechanical rotational tools were used in 66% of cases, and a total of 29 leads were removed. Procedural success was accomplished in 93% of cases. There was 1 (7%) intraprocedural complication and no procedure-related mortality.

Conclusions: The development of a lead management program is feasible, safe, and effective in underdeveloped countries.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9795241PMC
http://dx.doi.org/10.1016/j.hroo.2022.07.012DOI Listing

Publication Analysis

Top Keywords

lead extraction
16
transvenous lead
8
extraction program
8
underdeveloped countries
8
procedural success
8
lead
5
patients
5
feasibility safety
4
safety transvenous
4
extraction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!