Analysis of breast follow-up results in patients after polyacrylamide hydrogel (PAAG) or silicone prosthesis removal.

J Plast Reconstr Aesthet Surg

Department of Burns & Plastic Surgery, Nanjing Drum Tower Hospital, the Affiliated Hospital of Medical School of Nanjing University, Nanjing, China. Electronic address:

Published: February 2023

Background: Polyacrylamide hydrogel has been prohibited since 2006 due to numerous complications. Unsatisfactory breast contour was always observed in patients after PAAG removal. The same occurred in patients after silicone prosthesis removal. We attempt to compare and analyze the difference in postoperative breast conditions and pathology between the two groups.

Methods: We retrospectively reviewed the data of patients who underwent PAAG or silicone prosthesis removal between 2011 and 2021. The BREAST-Q was used to evaluate the follow-up results, including satisfaction with breasts, physical well-being, psychosocial well-being, sexual well-being, and the operation.

Results: A total of 63 patients were analyzed. The PAAG group complained of more lumps or indurations (p = 0.004), benefited less from operations as for symptomatic relief (p = 0.002), and had more chronic inflammation(p = 0.000) than the silicone group. No breast cancer was found. All the Breast-Q scores were lower in the PAAG group than in the silicone group, and there was a significant difference in satisfaction with physical well-being (p = 0.035). Besides, patients without symptoms tended to score higher in all aspects of Breast-Q than patients with symptoms after removal. The two groups (symptom & no symptom) differed in psychosocial well-being (p = 0.043) and satisfaction with operation (p = 0.048).

Conclusions: The breast contour of patients after PAAG or silicone prosthesis removal was worse than before. Early removal of PAAG before complications arise may result in a better surgical benefit. There is no doubt that PAAG are harmful both physically and psychologically. All patients are suggested to have PAAG injections removed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjps.2022.11.063DOI Listing

Publication Analysis

Top Keywords

silicone prosthesis
16
prosthesis removal
16
paag silicone
12
patients
9
paag
9
polyacrylamide hydrogel
8
breast contour
8
patients paag
8
physical well-being
8
psychosocial well-being
8

Similar Publications

Exploring diverse biomaterials and implants in the ear, nose, and throat by understanding adverse effects and post-usage events. Literature was obtained from Scopus, PubMed, Google Scholar, and Web of Science. A comprehensive analysis was conducted on original research studies, case reports, and case series spanning from December 2010 to May 2022.

View Article and Find Full Text PDF

BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.

View Article and Find Full Text PDF

Low-cost male urogenital simulator for penile implant surgery training: a 3D printing approach.

3D Print Med

January 2025

Department of Surgical & Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Background: Penile implant surgery is the standard surgical treatment for end-stage erectile dysfunction. However, the growing complexity of modern high-tech penile prostheses has increased the demand for more practical training opportunities. The most advanced contemporary training methods involve simulation training using cadavers, with costs exceeding $5,000 per cadaver, inclusive of biohazard fees.

View Article and Find Full Text PDF

Complete expiratory central airway collapse at general anesthesia recovery: a case report.

J Int Med Res

January 2025

Department of Anesthesiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China.

Expiratory central airway collapse is a degenerative tracheobronchial disease that is often overlooked because of its nonspecific clinical features. A man was admitted for evaluation of tracheal nodules. Following bronchoscopic biopsy, a significant increase in airway pressure occurred during anesthesia recovery.

View Article and Find Full Text PDF

Full-arch implant-supported rehabilitation using reverse scan technique: A case report.

J Oral Implantol

January 2025

Department of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City, Vietnam.

The reverse scan technique offers several advantages, such as improvements of accuracy and visibility of critical anatomical structures, minimizing chair time, and providing better patient comfort. This was a case report successfully employing the reverse scan technique. A 72-year-old male patient desired to restore his teeth in both jaws, as he experienced difficulty eating and had never worn dentures.

View Article and Find Full Text PDF