A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Artificial Urinary Sphincter Cuff Downsizing Improves Continence and Patient Satisfaction in Cases of Sub-cuff Atrophy. | LitMetric

Purpose: The management of artificial urinary sphincter sub-cuff atrophy remains controversial, and clinical outcomes are underreported. We intend to examine the impact of cuff downsizing in cases of isolated sub-cuff atrophy.

Materials And Methods: We reviewed our prospectively collected, institutionally approved quality improvement database for this study from 2011 to 2022. Institutional Review Board approval was obtained for the analysis. Sub-cuff atrophy in patients with post-prostatectomy incontinence was diagnosed with a clinical presentation of recurrent urinary leakage, serial pelvic films, cystoscopy, and patient evaluation. Outcomes were assessed with pad use, subjective measures, and American Urological Association Symptom Score scores.

Results: During the study interval, 871 encounters for artificial urinary sphincter placement were identified, 229 for revision or replacement, of which cuff downsizing for isolated cases of sub-cuff atrophy occurred in 34. Downsizing took place after a median of 6.5 years after initial artificial urinary sphincter placement. Of the patients, 97% reported subjective improvement and 93% experienced a decrease in daily incontinence pad use, with a mean±SD decrease of 2.2±1.45 pads ( < .01). American Urological Association Symptom Score bother scores decreased from pre-downsizing values by a mean±SD of 1.5±1.4 ( = .01). After a median follow-up of 1.8 years after downsizing, 24 (70.6%) of downsized cuffs remained in place, 2 (5.9%) were further downsized, 2 (5.9%) required replacement for mechanical failure, 4 (11.8%) underwent removal for erosion, and 2 (5.9%) underwent replacement for a herniated pressure regulating balloon.

Conclusions: When diagnosed using objective criteria, cuff downsizing improves continence and patient satisfaction in cases of sub-cuff atrophy.

Download full-text PDF

Source
http://dx.doi.org/10.1097/JU.0000000000003138DOI Listing

Publication Analysis

Top Keywords

sub-cuff atrophy
20
artificial urinary
16
urinary sphincter
16
cuff downsizing
16
cases sub-cuff
12
downsizing improves
8
improves continence
8
continence patient
8
patient satisfaction
8
satisfaction cases
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!