A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mechanically and physiologically optimizing prosthetic elevated vacuum systems in people with transtibial amputation: a pilot study. | LitMetric

Introduction: The most suitable elevated vacuum (EV) pressure may differ for each individual prosthesis user depending on suspension needs, socket fit, prosthetic components, and health. Mechanical and physiological effects of EV were evaluated in an effort to determine the optimal vacuum pressure for three individuals.

Methods: Instrumented EV sockets were created based on the participants' regular EV sockets. Inductive distance sensors were embedded into the wall of the socket at select locations to measure limb movement relative to the socket. Each participant conducted an activity protocol while limb movement, limb fluid volume, and user-reported comfort were measured at various socket vacuum pressure settings.

Results: Increased socket vacuum pressure resulted in reduced limb-socket displacement for each participant; however, 81-93% of limb movement was eliminated by a vacuum pressure setting of 12 (approximately -9 inHg). Relative limb-socket displacement by sensor location varied for each participant, suggesting distinct differences related to socket fit or residual limb tissue content. The rate of limb fluid volume change and the change in socket comfort did not consistently differ with socket vacuum pressure, suggesting a more complex relationship unique to each individual.

Conclusions: Practitioners may use individual responses to optimize socket vacuum pressure settings, balancing mechanical and physiological effects of EV for improved clinical outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9793861PMC
http://dx.doi.org/10.1097/jpo.0000000000000396DOI Listing

Publication Analysis

Top Keywords

vacuum pressure
28
socket vacuum
16
limb movement
12
socket
9
vacuum
8
elevated vacuum
8
socket fit
8
mechanical physiological
8
physiological effects
8
limb fluid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!