Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Persons with stroke often have difficulty achieving target heart rate (HR) during graded exercise testing (GXT), which is known to limit test sensitivity for detecting clinically relevant cardiac conditions. A novel Recumbent Stepper 3-minute (RS 3Min) "all out" test may increase sensitivity of stress testing after stroke.
Objective: To determine the feasibility of adding the RS 3Min test after GXT among persons after stroke.
Design: A within-participant, nonrandomized, repeated measures design.
Setting: Rehabilitation research laboratory and cardiovascular stress laboratory PARTICIPANTS: Fifteen participants with chronic stroke (56.7 ± 9.6 years; 6.4 ± 4.3 years post stroke; 8 male).
Interventions: All participants randomly completed (1) a symptom-limited treadmill GXT and (2) a symptom-limited RS GXT followed by RS 3Min critical power test.
Main Outcome Measures: HR, ratings of perceived exertion, oxygen consumption, respiratory exchange ratio, and power output measured continuously during each test. Blood pressure measured every 2 minutes and or immediately post exercise. P value set at p < .05 from omnibus test for a significant difference among protocols.
Results: The RS 3Min test had a significantly higher rate of achieving target HR compared to the RS GXT (9/14 vs 4/14, p = .02) and was not significantly different from the treadmill GXT (9/14 vs 5/14, p = .09). Minimum power output during the RS 3Min was significantly higher than peak power output during the RS GXT (110 ± 41 W vs. 84 ± 22 W, p = .02) with 12/15 participants reaching a VO plateau.
Conclusions: Although additional studies with randomized designs are needed, a novel RS 3Min "all out" test appears to be a promising method for enhancing test sensitivity in cardiovascular screening after stroke, while providing a potentially valid measure of critical power.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10307922 | PMC |
http://dx.doi.org/10.1002/pmrj.12940 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!