Reduced Early Revision Surgery and Medical Complications in Computer-assisted Knee Arthroplasty Compared With Non-computer-assisted Arthroplasty.

J Am Acad Orthop Surg

From the Department of Orthopaedic Surgery, George Washington University Hospital, Washington, DC (Malyavko, Fuller, and Agarwal), the Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA (Cohen), the Department of Orthopaedic Surgery, Virginia Commonwealth University Health, Richmond, VA (Golladay), and the Department of Orthopaedic Surgery, Adult Reconstruction Division, Johns Hopkins University, Columbia, MD (Thakkar).

Published: January 2023

Background: Computer assistance can help surgeons achieve mechanical accurate alignment, but the clinical effect of this technology in different arthroplasty types remains controversial because of conflicting functional outcomes, revision rates, and complication rates. The goal of this study was to compare 90-day medical complications and 1 and 2-year revision surgeries after computer-assisted patellofemoral arthroplasty, unicompartmental knee arthroplasty (CA-UKA), bicompartmental knee arthroplasty (CA-BKA), and total knee arthroplasty (CA-TKA) with non-computer-assisted procedures.

Methods: A retrospective cohort analysis was conducted using the Mariner data set of the PearlDiver Patient Records Database from 2010 to 2018. Current Procedural Terminology codes were used to identify patients who underwent patellofemoral arthroplasty, unicompartmental knee arthroplasty, bicompartmental knee arthroplasty, and total knee arthroplasty with or without computer assistance for osteoarthritis. All included patients were followed up for 2 years. Univariate and multivariable analyses were conducted.

Results: On multivariable analysis, revision within 1 year was decreased in patients who underwent computer-assisted patellofemoral arthroplasty (odds ratio [OR]: 0.541, P = 0.031), CA-UKA (OR: 0.798, P = 0.019), and computer-assisted bicompartmental knee arthroplasty (OR: 0.186, P = 0.025) compared with the same surgeries without technology assistance. CA-TKA had decreased odds of revision for aseptic loosening at 2 years (OR: 0.789, P < 0.001). CA-UKA and CA-TKA had decreased risk of overall 90-day medical complications (OR: 0.838, P < 0.001; OR: 0.903, P < 0.001, respectively) and major complications (OR: 0.750, P = 0.004; OR: 0.822, P < 0.001, respectively).

Discussion: Complication rates and revision surgeries for all arthroplasty types were equivalent or more favorable when computer assistance was used during surgery. Our results quantify some early benefits to using computer assistance in total and partial knee arthroplasties.

Download full-text PDF

Source
http://dx.doi.org/10.5435/JAAOS-D-22-00596DOI Listing

Publication Analysis

Top Keywords

knee arthroplasty
32
computer assistance
16
arthroplasty
14
medical complications
12
patellofemoral arthroplasty
12
bicompartmental knee
12
knee
9
arthroplasty types
8
complication rates
8
90-day medical
8

Similar Publications

Objective: Central sensitization (CS) is associated with quality of life (QOL) after total knee arthroplasty (TKA). However, how CS changes after TKA and whether these changes have clinical relevance remain unclear. Therefore, this study was conducted to identify changes in CS after TKA and to assess the clinical significance of these changes.

View Article and Find Full Text PDF

Background: Spacer-type tibial osteotomy have been proven a novel and effective osteotomy to treat osteoarthritis, while lack of comparison with other surgical methods in younger patients. This study aims to evaluate the short-term clinical outcomes of spacer-type tibial osteotomy versus open wedge high tibial osteotomy (OWHTO) and unicompartmental knee arthroplasty (UKA) for Kellgren-Lawrence (K-L) grade 3-4 osteoarthritis (OA) in patients younger than 65 years.

Methods: This retrospective study analyzed a total of 224 patients with K-L grade 3-4 knee OA treated from March 2018 to November 2020.

View Article and Find Full Text PDF

Individualized total knee arthroplasty achieves better functional results than off-the-shelf implants in patients undergoing personalized coronal alignment.

Knee

January 2025

IULS-University Institute for Locomotion and Sports, Pasteur 2 Hospital, University Côte d'Azur, Nice, France; ICARE Team, Côte d'Azur University, Inserm, CNRS, Valrose Institute of Biology, Nice, France. Electronic address:

Background: Several studies have demonstrated the interest in patient-specific custom cutting guides in total knee arthroplasty (TKA), but clinical improvement remains debated. The purpose of this study was to evaluate the functional outcomes (Forgotten Joint Score, FJS) of patients undergoing individualized TKA compared with those receiving off-the-shelf (OTS) implants, both using patient-specific cutting guides with personalized alignment over a minimum follow up period of 12 months. We hypothesized that individualized TKA demonstrates significantly better functional outcomes than OTS TKA (FJS and percentage of patients reaching the minimum clinically important difference).

View Article and Find Full Text PDF

Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!