Objective: The present investigation intends to identify the optimal radiotherapy treatment plan for synchronous bilateral breast cancer (SBBC) using dosimetric and radiobiological indexes for three techniques, namely, helical tomotherapy (HT), volumetric modulated arc therapy (VMAT), and intensity-modulated radiotherapy (IMRT).

Methods: Twenty SBBC treated female patients treatment planning data (average age of 52.5 years) were used as the sample for the present study. Three different plans were created using 50 Gy in a 25 fraction dose regime. Poisson, Niemierko, and LKB models were applied for calculating normal tissue complication probability (NTCP) and tumour control probability (TCP).

Result: The target average dose comparison between IMRT with HT and VMAT with HT was highly substantial (P=0.001). The percentage of TCP for IMRT, VMAT, and HT in the Poisson model were 93.70±0.28, 94.68±0.30, and 94.34±0.57, respectively (p<0.05). The dose maximum was lower for the whole lung in the HT plan, with an average dose of 49.31Gy±3.9 (p<0.009). The NTCP values of both Niemierko and LKB models were lower for the heart, lungs, and liver for the IMRT plan.

Conclusion: The sparing of organs at risk was higher in the HT plan dosimetrically, and the TCP was higher in the three techniques. The comparison between the three techniques shows that the IMRT and HT techniques could be considered for treating SBBC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9971452PMC
http://dx.doi.org/10.31557/APJCP.2022.23.12.4233DOI Listing

Publication Analysis

Top Keywords

dosimetric radiobiological
8
volumetric modulated
8
modulated arc
8
arc therapy
8
helical tomotherapy
8
synchronous bilateral
8
bilateral breast
8
breast cancer
8
imrt vmat
8
radiobiological comparison
4

Similar Publications

Purpose: To evaluate the dosimetric, radiobiological, and toxicity differences between different cylinder diameters (d) in high-dose-rate three-dimensional computed-tomography-guided vaginal brachytherapy (VBT) for early-stage endometrial cancer (EC).

Methods: From January 2019 to January 2024, postoperative EC patients treated with exclusive VBT using cylinders were classified by the cylinder diameter (d ≤ 2.6 cm: small-size; d ≥ 3.

View Article and Find Full Text PDF

Purpose: This study by the EANM radiobiology working group aims to analyze the efficacy and toxicity of targeted radionuclide therapy (TRT) using radiopharmaceuticals approved by the EMA and FDA for neuroendocrine tumors and prostate cancer. It seeks to understand the correlation between physical parameters such as absorbed dose and TRT outcomes, alongside other biological factors.

Methods: We reviewed clinical studies on TRT, focusing on the relationship between physical parameters and treatment outcomes, and applying basic radiobiological principles to radiopharmaceutical therapy to identify key factors affecting therapeutic success.

View Article and Find Full Text PDF

The radiobiological mechanisms behind the favorable response of tissues to microbeam radiation therapy (MRT) are not fully described yet. Among other factors, the differential action to tumor and normal tissue vasculature is considered to contribute to MRT efficacy. This computational study evaluates the relevance of tumor growth stage and associated vascular redistribution to this effect.

View Article and Find Full Text PDF

Introduction: Spatially Fractionated Radiation Therapy (SFRT) is an unconventional therapeutic approach with the potential to disrupt the classical paradigms of conventional radiation therapy. The high spatial dose modulation in SFRT is believed to activate distinct radiobiological mechanisms which lead to remarkable increases in normal tissue tolerance. To make optimal use of SFRT and its benefits, a deeper understanding of the biological response and its relationship with the complex dosimetric and geometric components of SFRT is essential.

View Article and Find Full Text PDF

Background: FLASH radiation therapy (RT) offers a promising avenue for the broadening of the therapeutic index. However, to leverage the full potential of FLASH in the clinical setting, an improved understanding of the biological principles involved is critical. This requires the availability of specialized equipment optimized for the delivery of conventional (CONV) and ultra-high dose rate (UHDR) irradiation for preclinical studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?