A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Filtering Pseudo-Bleb Secondary to Sutured Posterior Chamber Intraocular Lens with Implications for Ocular Surgery in Marfan Syndrome. | LitMetric

A 51-year-old female Caucasian patient with a history of Marfan syndrome and multiple previous bilateral ocular surgeries presented with increasing discomfort, epiphora, and blurred vision in her right eye for a few months. On examination, we found an overhanging cystic Seidel-positive filtering pseudo-bleb with hypotony in her right eye and a smaller Seidel-negative filtering pseudo-bleb in the left eye secondary to sutured intraocular lens (IOL) in both eyes. Intraoperatively, two full-thickness scleral defects were found close to the limbus, suggesting a melting flap in the location of the previous sutured IOL implant in the right eye. The defects were plugged with two pieces of donor sclera and covered with a larger donor scleral patch, the ischemic conjunctiva was excised, and the remaining healthy conjunctiva was advanced and sutured along the limbus. At last follow-up, intraocular pressure and vision in the right eye increased to preoperative levels, and no pseudo-bleb or leak was detected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9811232PMC
http://dx.doi.org/10.4274/tjo.galenos.2022.54936DOI Listing

Publication Analysis

Top Keywords

filtering pseudo-bleb
12
secondary sutured
8
intraocular lens
8
marfan syndrome
8
vision eye
8
eye
5
pseudo-bleb secondary
4
sutured
4
sutured posterior
4
posterior chamber
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!