Background And Purpose: This study aimed to investigate the potential contribution of quantitative measurements of dural venous sinuses to the diagnosis of idiopathic intracranial hypertension (IIH) and the relationship between IIH and dural venous sinus dimensions on 3D post-gadolinium T1-weighted magnetic resonance (MR) images.

Material And Methods: A total of 129 individuals (57 IIH patients and 72 controls) who complained of headache and underwent both magnetic resonance venography (MRV) and precontrast/postcontrast 3D T1-weighted MR imaging between 2018 and 2021 were included in this retrospective study. Dural venous sinus and jugular vein diameters were measured in all cases using post-gadolinium 3D T1 TFE images. The presence of transverse sinus (TS) hypoplasia and occipital sinus variation, the number and size of arachnoid granulations in the TS, and the presence of brain parenchymal herniation were also evaluated. Cut-off values that maximized accurate diagnosis of IIH were established on the receiver operating characteristic curve. The sensitivity and specificity of the diagnosis of IIH based on quantitative measurements of the dural sinus were calculated.

Results: The ratios of the maximum to minimum TS diameters and the minimum TS diameters to minimum sigmoid sinus (SS) diameters were significantly higher in IIH patients than in the control group (p < 0.001). The diagnostic sensitivity and specificity values of TS/TS and TS/SS parameters for the detection of IIH were 84.2%, 84.7% and 83.3%, 84.2%, respectively.

Conclusion: Practical measurements from multiplanar T1 sequences can be useful for both quantitative assessment and overcoming misinterpretation due to anatomical variation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00062-022-01244-0DOI Listing

Publication Analysis

Top Keywords

quantitative measurements
12
dural venous
12
dural sinus
8
idiopathic intracranial
8
intracranial hypertension
8
measurements dural
8
venous sinus
8
magnetic resonance
8
diagnosis iih
8
minimum diameters
8

Similar Publications

Evaluation of a Point-of-Care-Viscoelastic Coagulation Device in Hispaniolan Amazon Parrots ().

J Avian Med Surg

January 2025

Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA.

Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.

View Article and Find Full Text PDF

Objectives: Intrathecal baclofen (ITB) therapy is well documented as an effective treatment option for severe spasticity. Before ITB implantation, trials are conducted to evaluate efficacy, safety, and candidate suitability. While many centers conduct ITB trials, appropriate physical assessment has not been fully established.

View Article and Find Full Text PDF

Background: The aim of this quantitative study conducted with 5008 individuals aged 15 and above in 12 provinces across Turkey was to determine the prevalence and significant variables of gambling behavior in our country and to examine the gambling behaviors, perceptions, thoughts, and attitudes of this population towards gambling. The goal is to generate concrete, original, culturally sensitive, feasible, and effective recommendations for preventive and risk-reducing policies. It is the first and only comprehensive investigation into gambling behavior in Turkey, offering guidance in this field.

View Article and Find Full Text PDF

This study presents a comprehensive method for detecting debonding defects in concrete-filled steel tube (CFST) structures using wave propagation analysis with externally attached piezoelectric ceramic sensors. Experimental tests and numerical simulations were conducted to evaluate the sensitivity and accuracy of two measurement techniques-the flat and oblique measurement methods-in detecting debonding defects of varying lengths and heights. The results demonstrate that the flat measurement method excels in detecting debonding height, while the oblique method is more effective for detecting debonding length.

View Article and Find Full Text PDF

Mobility tasks like the Timed Up and Go test (TUG), cognitive TUG (cogTUG), and walking with turns provide insights into the impact of Parkinson's disease (PD) on motor control, balance, and cognitive function. We assess the test-retest reliability of these tasks in 262 PD participants and 50 controls by evaluating machine learning models based on wearable-sensor-derived measures and statistical metrics. This evaluation examines total duration, subtask duration, and other quantitative measures across two trials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!