A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

SARS-CoV-2 detecting rapid metasurface-based sensor. | LitMetric

SARS-CoV-2 detecting rapid metasurface-based sensor.

Diam Relat Mater

Department of Electrical Engineering, College of Engineering, Jouf University, Sakaka 72388, Saudi Arabia.

Published: February 2023

We have proposed a novel approach to detect COVID-19 by detecting the ethyl butanoate which high volume ratio is present in the exhaled breath of a COVID-19 infected person. We have employed a refractive index sensor (RIS) with the help of a metasurface-based slotted T-shape perfect absorber that can detect ethyl butanoate present in exhaled breath of COVID-19 infected person with high sensitivity and in-process SARS-CoV-2. The optimized structure of the sensor is obtained by varying several structure parameters including structure length and thickness, slotted T-shape resonator length, width, and thickness. Sensor's performance is evaluated based on numerous factors comprising of sensitivity, Q factor, detection limit, a figure of merit (FOM), detection accuracy, and other performance defining parameters. The proposed slotted T-shape RIS achieved the largest sensitivity of 2500 nm/RIU, Q factor of 131.06, a FOM of 131.58 RIU, detection limit of 0.0224 RIU.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9780024PMC
http://dx.doi.org/10.1016/j.diamond.2022.109644DOI Listing

Publication Analysis

Top Keywords

slotted t-shape
12
ethyl butanoate
8
exhaled breath
8
breath covid-19
8
covid-19 infected
8
infected person
8
detection limit
8
sars-cov-2 detecting
4
detecting rapid
4
rapid metasurface-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!