Background: Intraoperative awareness is the second most common complication of surgeries, and it negatively affects patients and healthcare professionals. Based on the limited previous studies, there is a wide variation in the incidence of intraoperative awareness and in the practices and attitudes toward depth of anesthesia (DoA) monitoring among healthcare systems and anesthesiologists. This study aimed to evaluate the Jordanian anesthesiologists' practice and attitudes toward DoA monitoring and estimate the event rate of intraoperative awareness among the participating anesthesiologists.

Methods: A descriptive cross-sectional survey of Jordanian anesthesiologists working in public, private, and university hospitals was utilized using a questionnaire developed based on previous studies. Practice and attitude in using DoA monitors were evaluated. Anesthesiologists were asked to best estimate the number of anesthesia procedures and frequency of intraoperative awareness events in the year before. Percentages and 95% Confidence Intervals (95%CI) were reported and compared between groups using chi-square tests.

Results: A total of 107 anesthesiologists responded and completed the survey. About one-third of the respondents (34.6%; 95% CI 26.1-44.2) had never used a DoA monitor and only 6.5% (95% CI 3.1-13.2) reported using it as a "daily practice". The use of a DoA monitor was associated with experience and type of health sector. However, 81.3% (95% CI 66.5-83.5) believed that currently available DoA monitors are effective for DoA monitoring and only 4.7% (95%CI 1.9-10.8) reported it as being "invalid". Most respondents reported that the main purpose of using a DoA monitor was to prevent awareness (86.0%; 95%CI 77.9-91.4), guide the delivery of anesthetics (63.6%; 95%CI 53.9-72.2), and reduce recovery time (57%; 95%CI 47.4-66.1). The event rate of intraoperative awareness was estimated at 0.4% among participating anesthesiologists. Most Jordanian hospitals lacked policy intending to prevent intraoperative awareness.

Conclusions: Most anesthesiologists believed in the role of DoA monitors in preventing intraoperative awareness, however, their attitudes and knowledge are inadequate, and few use DoA monitors in routine practices. In Jordan, large efforts are needed to regulate the use of DoA monitoring and reduce the incidence of intraoperative awareness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9793501PMC
http://dx.doi.org/10.1186/s12871-022-01941-wDOI Listing

Publication Analysis

Top Keywords

intraoperative awareness
32
doa monitoring
16
doa monitors
16
event rate
12
doa monitor
12
doa
11
intraoperative
9
awareness
9
depth anesthesia
8
jordanian anesthesiologists
8

Similar Publications

The AORN surgical attire guideline promotes cleanliness in the perioperative environment to minimize patients' risks of developing surgical site infections. In 2020, the surgical attire guideline adherence decision-making model was published based on findings from a study involving New England intraoperative team members. To explore the model's transferability across the United States, we replicated the 2020 study with intraoperative personnel who did not live or work in New England.

View Article and Find Full Text PDF

Gout is a disorder of purine metabolism described by the deposition of monosodium urate crystals with rare involvement in the head and neck. This is the first laryngeal gout case reported in Sabah, Malaysia. A 50-year-old gentleman with a long history of gouty arthritis presented with acute painless anterior neck swelling for two weeks.

View Article and Find Full Text PDF

Distal femoral anterior cortical perforation is a rare complication of intramedullary nailing for proximal femur fractures. Awareness and intraoperative preventive measures are key to minimizing the risk of this complication. We report a case of a patient who experienced an anterior cortical breach of the distal femur during routine antegrade nailing for an intertrochanteric fracture, which was attributed to a sclerotic lesion in the distal femur.

View Article and Find Full Text PDF

Introduction Orthopaedic surgery frequently involves the use of intra-operative radiographs, commonly taken with surgeons standing in close proximity to the X-ray machine. Radiation training and appropriate radiation protection minimise the harm that surgeons can face from ionising radiation. This study evaluates the current state of radiation training and protective equipment available to orthopaedic surgeons in the East of England.

View Article and Find Full Text PDF

Purpose: Femur fractures are among the most common fractures treated surgically, representing a significant challenge for the orthopedic surgeon. Peri-implant femoral fractures (PIFFs) represent a rare complication of the surgical treatment. It is necessary to pay attention during osteosynthesis, evaluating not only the fracture site but the entire femoral skeletal structure, the characteristics of the fracture, the health comorbidities, and the risk of malunion and pseudarthrosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!