Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Single-visit radiotherapy (RT) is beneficial for patients requiring pain control and can limit interruptions to systemic treatments. However, the requirement for a dedicated planning CT (pCT)-scan can result in treatment delays. We developed a workflow involving preplanning on available diagnostic CT (dCT) imaging, followed by online plan adaption using a cone-beam CT (CBCT)-scan prior to RT-delivery, in order to account for any changes in anatomy and target position.
Methods: Patients previously treated with palliative RT for bone metastases were selected from our hospital database. Patient dCT-images were deformed to treatment CBCTs in the Ethos platform (Varian Medical Systems) and a synthetic CT (sCT) generated. Treatment quality was analyzed by comparing a coverage of the V95% of the planning/clinical target volume and different organ-at-risk (OAR) doses between adapted and initial clinical treatment plans. Doses were recalculated on the CBCT and sCT in a separate treatment planning system. Adapted plan doses were measured on-couch using an anthropomorphic phantom with a Gafchromic EBT3 dosimetric film and compared to dose calculations.
Results: All adapted treatment plans met the clinical goals for target and OARs and outperformed the original treatment plans calculated on the (daily) sCT. Differences in V95% of the target volume coverage between the initial and adapted treatments were <0.2%. Dose recalculations on CBCT and sCT were comparable, and the average gamma pass rate (3%/2 mm) of dosimetric measurements was 98.8%.
Conclusions: Online daily adaptive RT using dCTs instead of a dedicated pCT is feasible using the Ethos platform. This workflow has now been implemented clinically.