Introduction: Plasma-measured tau phosphorylated at threonine 217 (p-tau217) is a potential non-invasive biomarker of Alzheimer's disease (AD). We investigated whether plasma p-tau217 predicts subsequent cognition and positron emission tomography (PET) markers of pathology in autosomal dominant AD.

Methods: We analyzed baseline levels of plasma p-tau217 and its associations with amyloid PET, tau PET, and word list delayed recall measured 7.61 years later in non-demented age- and education-matched presenilin-1 E280A carriers (n = 24) and non-carrier (n = 20) family members.

Results: Carriers had higher plasma p-tau217 levels than non-carriers. Baseline plasma p-tau217 was associated with subsequent amyloid and tau PET pathology levels and cognitive function.

Discussion: Our findings suggest that plasma p-tau217 predicts subsequent brain pathological burden and memory performance in presenilin-1 E280A carriers. These results provide support for plasma p-tau217 as a minimally invasive diagnostic and prognostic biomarker for AD, with potential utility in clinical practice and trials.

Highlights: Non-demented presenilin-1 E280A carriers have higher plasma tau phosphorylated at threonine 217 (p-tau217) than do age-matched non-carriers. Higher baseline p-tau217 is associated with greater future amyloid positron emission tomography (PET) pathology burden. Higher baseline p-tau217 is associated with greater future tau PET pathology burden. Higher baseline p-tau217 is associated with worse future memory performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10271963PMC
http://dx.doi.org/10.1002/alz.12906DOI Listing

Publication Analysis

Top Keywords

plasma p-tau217
28
p-tau217 associated
16
p-tau217 predicts
12
tau pet
12
presenilin-1 e280a
12
e280a carriers
12
pet pathology
12
higher baseline
12
baseline p-tau217
12
p-tau217
11

Similar Publications

: The objective of this study was to assess clinical decision-making associated with the use of a multi-analyte blood biomarker (BBM) test among patients presenting with signs or symptoms of mild cognitive impairment or dementia. : The Quality Improvement PrecivityAD2 (QUIP II) Clinician Survey (NCT06025877) study evaluated the clinical utility of the PrecivityAD2™ blood test in a prospective, single cohort of 203 patients presenting with symptoms of Alzheimer's disease (AD) or other causes of cognitive decline across 12 memory specialists. The PrecivityAD2 blood test (C2N Diagnostics, St.

View Article and Find Full Text PDF

Accuracy and clinical applicability of plasma tau 181 and 217 for Alzheimer's disease diagnosis in a memory clinic cohort.

J Neurol

January 2025

Alzheimer's Disease and Other Cognitive Disorders Unit, Neurology Service, Hospital Clínic de Barcelona, Fundació de Recerca Clínic - Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Universitat de Barcelona, Villaroel 170, 08036, Barcelona, Spain.

Plasma tau phosphorylated at threonine 181 (p-tau181) and 217 (p-tau217) have demonstrated high accuracy for Alzheimer's disease (AD) diagnosis, defined by CSF/PET amyloid beta (Aβ) positivity, but most studies have been performed in research cohorts, limiting their generalizability. We studied plasma p-tau217 and p-tau181 for CSF Aβ status discrimination in a cohort of consecutive patients attending an academic memory clinic in Spain (July 2019-June 2024). All patients had CSF AD biomarkers performed as part of their routine clinical assessment.

View Article and Find Full Text PDF

Background: For clinical implementation of Alzheimer's disease (AD) blood-based biomarkers (BBMs), knowledge of short-term variability, is crucial to ensure safe and correct biomarker interpretation, i.e., to capture changes or treatment effects that lie beyond that of expected short-term variability and considered clinically relevant.

View Article and Find Full Text PDF

Background: Blood-based biomarkers, especially P-tau217, have been gaining interest as diagnostic tools to measure Alzheimer disease (AD) pathology.

Methods: We developed a plasma P-tau217 chemiluminescent immunoassay using 4G10E2 and IBA493 as antibodies, a synthetic tau peptide as calibrator, and the Quanterix SP-X imager. Analytical validation performed in a College of American Pathologists-accredited CLIA laboratory involved multiple kit lots, operators, timepoints, and imagers.

View Article and Find Full Text PDF

Background And Objectives: Chronic kidney disease (CKD) is known to be associated with increased plasma phosphorylated tau217 (p-tau217) concentrations, potentially confounding the utility of plasma p-tau217 measurements as a marker of amyloid pathology in individuals with suspected Alzheimer disease (AD). In this study, we quantitatively investigate the relationship of plasma p-tau217 concentrations vs estimated glomerular filtration rate (eGFR) in individuals with CKD with and without amyloid pathology.

Methods: This was a retrospective examination of data from 2 observational cohorts from either the Mayo Clinic Study of Aging or the Alzheimer's Disease Research Center cohorts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!