Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A modulation of intensity with zero effort (MIEZE) setup is proposed for high-resolution neutron spectroscopy at momentum transfers up to 3 Å, energy transfers up to 20 meV and an energy resolution in the microelectronvolt range using both thermal and cold neutrons. MIEZE has two prominent advantages compared with classical neutron spin echo. The first is the possibility to investigate spin-depolarizing samples or samples in strong magnetic fields without loss of signal amplitude and intensity. This allows for the study of spin fluctuations in ferromagnets, and facilitates the study of samples with strong spin-incoherent scattering. The second advantage is that multi-analyzer setups can be implemented with comparatively little effort. The use of thermal neutrons increases the range of validity of the spin-echo approximation towards shorter spin-echo times. In turn, the thermal MIEZE option for greater ranges (TIGER) closes the gap between classical neutron spin-echo spectroscopy and conventional high-resolution neutron spectroscopy techniques such as triple-axis, time-of-flight and back-scattering. To illustrate the feasibility of TIGER, this paper presents the details of its implementation at the RESEDA beamline at FRM II by means of an additional velocity selector, polarizer and analyzer.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9721327 | PMC |
http://dx.doi.org/10.1107/S1600576722009505 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!