A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In-tube gel electromembrane extraction: A green strategy for the extraction of narcotic drugs from biological samples. | LitMetric

In-tube gel electromembrane extraction: A green strategy for the extraction of narcotic drugs from biological samples.

J Chromatogr A

Department of Environmental Geology, Research Institute of Applied Sciences (ACECR), Shahid Beheshti University, Tehran, Iran. Electronic address:

Published: January 2023

The development of green and miniature extraction methods is always a major and controversial challenge in the field of sample preparation. In this work, in-tube gel electromembrane extraction (IT-G-EME) was developed as a miniaturized extraction device for the extraction of six narcotic drugs (codeine, oxycodone, hydrocodone, tramadol, thebaine, and noscapine) from biological samples. A transparent capillary tube (∼6 cm) was used as a microextraction unit. The middle part of the tube was filled with a narrow plug (∼3 mm) of the agarose gel (3.0% w/v) as a membrane and the other sides were filled with aqueous extractant solution (pH 2.0, 20 µL) and sample solution (pH 5.0, 200 µL). By applying electrical potential (400 V), the target drugs with positive charge were migrated from sample solution toward the extractant solution through gel membrane during short extraction time (5 min). Then, the enriched analytes in extractant solution was analyzed by HPLC-UV. Under the optimized conditions, the calibration curves were linear within the permissible range of 10.0-1500 ng/mL (r ≥ 0.991). Limits of detection and extraction recoveries were in the range of 3.0-4.5 ng/mL and 61.9-86.9%, respectively. On the basis of four replications, the repeatability of the method was also evaluated in terms of intra- and inter-day RSDs (%), which did not exceed from 6.6 and 7.9%, respectively in aqueous media. The figures of merit were also assessed in biological samples. Eventually, the developed method was profitably used for simultaneous determination of narcotic drugs in the real urine and plasma samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2022.463714DOI Listing

Publication Analysis

Top Keywords

narcotic drugs
12
biological samples
12
extractant solution
12
in-tube gel
8
gel electromembrane
8
extraction
8
electromembrane extraction
8
extraction narcotic
8
sample solution
8
solution
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!