A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Contactless monitoring of respiratory rate (RR) and heart rate (HR) in non-acuity settings: a clinical validity study. | LitMetric

Objective: Patient monitoring in general wards primarily involves intermittent observation of temperature, heart rate (HR), respiratory rate (RR) and blood pressure performed by the nursing staff. Several hours can lapse between such measurements, and the patient may go unobserved. Despite the growing widespread use of sensors to monitor vital signs and physical activities of healthy individuals, most acutely ill hospitalised patients remain unmonitored, leaving them at an increased risk. We investigated whether a contactless monitoring system could measure vital parameters, such as HR and RR, in a real-world hospital setting.

Design: A cross-sectional prospective study.

Setting And Participants: We examined the suitability of employing a non-contact monitoring system in a low-acuity setup at a tertiary care hospital in India. Measurements were performed on 158 subjects, with data acquired through contactless monitoring from the general ward and dialysis unit.

Outcome Measures: Vital parameters (RR and HR) were measured using a video camera in a non-acuity setting.

Results: Three distinct combinations of contactless monitoring afforded excellent accuracy. Contactless RR monitoring was linearly correlated with Alice NightOne and manual counts, presenting coefficients of determination of 0.88 and 0.90, respectively. Contactless HR monitoring presented a coefficient of determination of 0.91. The mean absolute errors were 0.84 and 2.15 beats per minute for RR and HR, respectively.

Conclusions: Compared with existing Food and Drug Administration-approved monitors, the findings of the present study revealed that contactless monitoring of RR and HR accurately represented study populations in non-acuity settings. Contactless video monitoring is an unobtrusive and dependable method for monitoring and recording RR and HR. Further research is needed to validate its dependability and utility in other settings, including acute care.

Trial Registration Number: CTRI/2018/11/016246.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791412PMC
http://dx.doi.org/10.1136/bmjopen-2022-065790DOI Listing

Publication Analysis

Top Keywords

contactless monitoring
28
monitoring
10
contactless
8
respiratory rate
8
heart rate
8
non-acuity settings
8
monitoring general
8
monitoring system
8
vital parameters
8
monitoring respiratory
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!