A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Modification of the Inverted Internal Limiting Membrane Flap Technique without Heavy Liquids and Prone Posturing. | LitMetric

Primary closure of large macular holes remains challenging, and variations of inverted inner limiting membrane (ILM) flap surgery have been described. In the present retrospective, interventional, single-centre case series, we propose a superior flap design with minimal posturing. Eight eyes of eight patients (four women and four men) in the period between July 2020 and March 2022 underwent 23 G three-port vitrectomy with a superior inverted ILM flap and 20% SF endotamponade for a full thickness macular hole (MH) by the same experienced surgeon (F. M. H.). Seven MHs were classified as large (> 400 µm) and one as medium (250 - 400 µm). The mean MLD was 638.0 ± 166.4 µm (range: 353 - 851 µm). MH closure was achieved in all (8/8, 100%) patients with a single surgery. The median best-corrected visual acuity (BCVA) improved from 6/120 (Snellen) (range: finger counting [FC] to 6/19) preoperatively to 6/19 (range: FC to 6/9.5) after surgery, without any intra- or postoperative complications. The superior inverted ILM flap technique seems to be a safe and successful approach for the primary closure of large MHs. Further studies should investigate our proposed surgical technique on a larger population, potentially without air or gas endotamponade.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-1972-3275DOI Listing

Publication Analysis

Top Keywords

ilm flap
12
limiting membrane
8
flap technique
8
primary closure
8
closure large
8
superior inverted
8
inverted ilm
8
flap
5
modification inverted
4
inverted internal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!