When using off-axis digital image correlation (DIC) for non-contact, remote, and multipoint deflection monitoring of engineering structures, accurate calibration of the scale factor (SF), which converts image displacement to physical displacement for each measurement point, is critical to realize high-quality displacement measurement. In this work, based on the distortion-free pinhole imaging model, a generalized SF calibration model is proposed for an off-axis DIC-based video deflectometer. Then, the transversal relationship between the proposed SF calibration method and three commonly used SF calibration methods was discussed. The accuracy of these SF calibration methods was also compared using indoor rigid body translation experiments. It is proved that the proposed method can be degraded to one of the existing calibration methods in most cases, but will provide more accurate results under the following four conditions: (1) the camera's pitch angle is more than 20°, (2) the focal length is more than 25 mm, (3) the pixel size of the camera sensor is more than 5 um, and (4) the image y-coordinate corresponding to the measurement point after deformation is far from the image center.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9788336 | PMC |
http://dx.doi.org/10.3390/s222410010 | DOI Listing |
Clin Infect Dis
January 2025
Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Infectious Diseases, Respiratory Medicine and Critical Care, Berlin, Germany.
Background: Existing risk evaluation tools underperform in predicting intensive care unit (ICU) admission for patients with the Coronavirus Disease 2019 (COVID-19). This study aimed to develop and evaluate an accurate and calculator-free clinical tool for predicting ICU admission at emergency room (ER) presentation.
Methods: Data from patients with COVID-19 in a nationwide German cohort (March 2020-January 2023) were analyzed.
PLoS One
January 2025
Dirección General de Minería, República Dominicana.
This study investigates the geochemical characteristics of rare earth elements (REEs) in highland karstic bauxite deposits located in the Sierra de Bahoruco, Pedernales Province, Dominican Republic. These deposits, formed through intense weathering of volcanic material, represent a potentially valuable REE resource for the nation. Surface and subsurface soil samples were analyzed using portable X-ray fluorescence (pXRF) and a NixPro 2 color sensor validated with inductively coupled plasma optical emission spectrometry (ICP-OES).
View Article and Find Full Text PDFMedicine (Baltimore)
January 2025
Department of Thyroid and Breast Surgery, Hebei General Hospital, Shijiazhuang, Hebei Province, China.
To assess whether metabolic syndrome can be used as a reference index to evaluate the efficacy of neoadjuvant chemotherapy treatment for breast cancer (BC). Seventy cases of female BC patients who received neoadjuvant chemotherapy treatment and surgical treatment at the Glandular Surgery Department of Hebei Provincial People's Hospital from January 2021 to December 2023 were retrospectively collected, and clinical data such as puncture pathology were recorded. The clinical data were analyzed by 1-way analysis using the χ2 test, and further multifactorial logistic regression analysis was performed for statistically significant differences.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
January 2025
Department of Chemistry, National Kaohsiung Normal University, Kaohsiung City, Taiwan.
Pyrethroids are synthetic chemicals that account for 16% of the international insecticide market and have been shown to be of varying toxicity to different species. There are various methods available for detecting pyrethroids in agricultural products, but these products must be pre-treated to remove interference from the food matrix, such as through dispersion liquid-liquid microextraction (DLLME). This study employed two experimental design methods to optimize the continuous and discontinuous experimental parameters of DLLME and investigated whether DLLME combined with GC-NICI-MS is effective for detecting pyrethroids in agricultural products.
View Article and Find Full Text PDFBr J Radiol
January 2025
Radiotherapy Physics Dept, Ipswich Hospital, Ipswich, Suffolk, IP45PD, UK.
Objectives: To survey kilovoltage (kV) radiotherapy in the UK, updating a 2016 study, focussing on radiotherapy physics, including equipment quality control (QC) and radiation dosimetry, with information on installed equipment and clinical activity.
Methods: All UK radiotherapy physics departments (n = 68) were invited to complete a comprehensive survey. An analysis of the installed equipment base, patient numbers, clinical activity, QC testing and radiation dosimetry processes were undertaken.