Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The measurement of a time-varying magnetic field is different from a constant magnetic field, due to its field intensity variation with time. Usually, the time-varying magnetic field measurement converts the solution of the magnetic induction intensity into the calculation of the induced electromotive force (EMF); then, the magnetic induction intensity is obtained by the time integration of the EMF, but the process is vulnerable to external interference. In this paper, a non-steady state nuclear magnetic resonance (NSS-NMR) scheme for the measurement of a time-varying magnetic field is proposed. In a time-varying magnetic field environment, an RF excitation signal with a certain frequency bandwidth is applied to excite the nuclear spin system. The NSS-NMR signal, which varies with time in the frequency range corresponding to the frequency bandwidth of the RF excitation, could finally be obtained after a series of processing of the probe output signal. During the NSS-NMR experiment, an orthogonal dual-coil probe is adopted to synchronously generate the RF excitation and induce the probe output signal. Moreover, a directional coupler that utilized in the experiment outputs a reference signal from the coupling port for the subsequent signal processing. The experimental results show that the weak NSS-NMR signal is indeed observed. The longitudinal time-varying magnetic field ranges from 0.576 T to 0.582 T, which is inverted by the Larmor precession relationship, have been successfully detected based on the so-called NSS-NMR effect.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9783355 | PMC |
http://dx.doi.org/10.3390/s22249960 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!