Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Modern systems of intelligent sensors commonly use radio data transmission. Hand movement acquisition with the use of inertial sensors requires the processing and transmission of a relatively large amount of data, which may be associated with a significant load on the network structure. Network traffic limitation, without losing the quality of monitoring parameters from the sensor system, is therefore important for the functioning of the radio network which integrates both the teletransmission sensor system and the data acquisition server. The paper presents a wearable solution for hand movement acquisition, which uses data transmission in the Wi-Fi standard and contains 16 MEMS (Micro Electro Mechanical System) sensors. An adaptive algorithm to control radio data transmission for the sensor system has been proposed. The algorithm implemented in the embedded system controls the change of the frame length, the length of the transmission frame and the frequency of its sending, which reduces the load on the network router. The use of the algorithm makes it possible to reduce the power consumption by the sensor system by up to 19.9% and to limit the number of data transferred by up to about 91.6%, without losing the quality of the monitored signal. The data analysis showed no statistically significant differences (p > 0.05) between the signal reconstructed from the complete data and processed by the algorithm.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9781473 | PMC |
http://dx.doi.org/10.3390/s22249866 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!