Several methods could be used to measure the forces from skis or roller skis in cross-country skiing. Equipment that could measure medio-lateral forces may be of good help for investigating the relevant skating techniques. The aim of this study was to validate a pair of newly designed two-dimensional force measurement roller skis. The vertical and medio-lateral forces which were perpendicular to the body of the roller ski could be measured. Forces were resolved into the global coordinate system and compared with the force components measured by a force plate. A static and dynamic loading situation for the force measurement roller ski was performed to reveal the validity of the system. To demonstrate whether the force measurement roller ski would affect roller skiing performance on a treadmill, a maximum speed test with the V2 technique was performed by using both normal and force measurement roller skis. The force-time curves obtained by these two different force measurement systems were shown to have high similarity (coefficient of multiple correlations > 0.940). The absolute difference for the forces in the X and Z directions over one push-off cycle was 3.9−33.3 N. The extra weight (333 g) of the force measurement roller ski did not affect the performance of the skiers. Overall, the newly designed two-dimensional force measurement roller ski in this study is valid for use in future research during daily training for skate skiing techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9786070PMC
http://dx.doi.org/10.3390/s22249856DOI Listing

Publication Analysis

Top Keywords

force measurement
32
measurement roller
28
roller ski
24
roller skis
12
roller
10
force
9
measurement
8
medio-lateral forces
8
newly designed
8
designed two-dimensional
8

Similar Publications

Background: Balance impairment is one of the causes of the risk of falls among all age groups and is a continuing threat to morbidity and mortality across the world. Previous studies stated that the vestibular system is affected in middle-aged population, which leads to imbalance and a high risk of falls. There is a lack of research in this account so this study has been done to find the effect of Cawthorne and Cooksey exercise in vestibular rehabilitation on balance control and the risk of falls among middle-age population.

View Article and Find Full Text PDF

Sensorless model-based tension control for a cable-driven exosuit.

Wearable Technol

December 2024

Sensory Motor Systems Lab, Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland.

Cable-driven exosuits have the potential to support individuals with motor disabilities across the continuum of care. When supporting a limb with a cable, force sensors are often used to measure tension. However, force sensors add cost, complexity, and distal components.

View Article and Find Full Text PDF

Temperature-Dependent Formation of Carbon Nanodomains in Silicon Oxycarbide Glass-A Reactive Force Field MD Study.

J Phys Chem C Nanomater Interfaces

January 2025

Institute of General, Inorganic and Theoretical Chemistry Center for Chemistry and Biomedicine, University of Innsbruck, Innrain 80-82, A-6020 Innsbruck, Austria.

Novel anode materials for lithium-ion batteries (LIBs) are constantly being explored to further improve battery performance. In this work, ReaxFF molecular dynamics (MD) simulations are performed to model the early stages in the synthesis of nanostructured silicon carbide (SiC), which is one such promising material. The focus lies on its precursor, silicon oxycarbide glass of composition (SiOC) (17 mol% Si, 28 mol% O, and 54 mol% C), in the following referred to as SiOC.

View Article and Find Full Text PDF

Establishing the UHB doctor wellbeing group as a model for sustainable change in improving resident doctor wellbeing.

Future Healthc J

March 2025

University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Mindelsohn Way, Edgbaston, Birmingham, B15 2GW, United Kingdom.

Significant wellbeing concerns have been reported nationally among resident doctors. A peer-led survey at University Hospitals Birmingham NHS Foundation Trust revealed high burnout risk and dissatisfaction. The Doctor Wellbeing Group (DWG) was established to address these multifaceted concerns by supporting resident doctors to run quality improvement projects to improve working conditions, with consultant supervision and regular reports to stakeholders.

View Article and Find Full Text PDF

Neuromuscular electrical stimulation producing low evoked force elicits the repeated bout effect on muscle damage markers of the elbow flexors.

Sports Med Health Sci

March 2025

Applied Neuromuscular Physiology Laboratory, Department of Kinesiology, Applied Health, and Recreation, Oklahoma State University, Stillwater, OK, 74075, USA.

This study examined the repeated bout effect (RBE) on muscle damage markers following two bouts of neuromuscular electrical stimulation (NMES) in untrained individuals. Following familiarization, participants received 45 consecutive NMES to the biceps brachii at an intensity that produced low evoked force for the elbow flexors. Muscle damage markers (maximal voluntary isometric contraction [MVIC], elbow range of motion [ROM], muscle soreness via visual analogue scale [VAS] scores, pressure pain threshold [PPT], and muscle thickness) were measured before (PRE), after (POST), 1 day after (24 POST), and 2 days after (48 POST) NMES.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!