One trend in tissue engineering and regenerative medicine is the development of degradable composite polymers. The aim of this study was the comprehensive analysis of Polylactic acid (PLA)/Polyhydroxybutyrate (PHB) + Hydroxyapatite (HA)/Tricalcium phosphate (TCP) material from filament production to mechanical testing of samples with different infills and the production of an implant replacement for an intervertebral disc. Filament Maker-Composer 450 (3devo; Netherlands) was used to produce filaments. Experimental samples and the implant for the intervertebral disc were made using FDM technology using a DeltiQ2 3D printer (Trilab, Czech Republic). Mechanical testing of experimental samples was performed on an Inspekt TABLE 5 kN (Hegewald & Peschke, Nossen, Germany). Microscopic analysis, cytotoxicity test, and filament diameter analysis using descriptive statistics were also part of the focus. The results of the analysis of the diameter of the filament show that the filament meets the prescribed standard. The cytotoxicity test for PLA/PHB + HA/TCP material showed no toxicity. Microscopic analysis showed an even distribution of the ceramic component in the composite polymer. Mechanical testing showed a reduction in mechanical properties with 75% and 50% of the filling of experimental samples. All experimental samples subjected to mechanical testing showed higher tensile and compressive strength values compared to the values of the mechanical properties of vertebral trabecular bones, as reported in the literature. It can therefore be concluded that the material under investigation, PLA/PHB + HA/TCP appears to be a suitable candidate for hard tissue replacement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9784836 | PMC |
http://dx.doi.org/10.3390/polym14245357 | DOI Listing |
Clin Oral Investig
January 2025
Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain.
Objectives: This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments.
Materials And Methods: A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer's recommended torque.
Clin Implant Dent Relat Res
February 2025
Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA.
Objectives: This study evaluated different designs of the conical implant-abutment connection (IAC) and their resistance to microgap formation under oblique loads as specified by the ISO standard for testing dental implants. Also evaluated was the effect of deviations from the ISO specifications on the outcomes.
Methods: Finite element analysis was conducted to compare the microgap formation and stress distribution among three conical IAC designs (A, B, and C) in two loading configurations: one compliant with ISO 14801 and one with a modified load adaptor (non-ISO).
Adv Sci (Weinh)
January 2025
Department of Rheumatology and Clinical Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117, Berlin, Germany.
Fractures, with a yearly incidence of 1.2%, can lead to healing complications in up to 10% of cases. The angiogenic stimulant deferoxamine (DFO) is recognized for enhancing bone healing when administered into the fracture gap.
View Article and Find Full Text PDFScientificWorldJournal
January 2025
Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.
While polyethylene terephthalate glycol (PETG) is widely used in orthodontic appliances such as clear aligners and retainers, there is limited experimental data assessing its performance under functional stresses, such as those encountered during dental movements and palatal expansion. This study aims to evaluate the ability of PETG thermoplastic material to withstand deformation under functional and expansion forces, specifically within the context of orthodontic applications. To estimate the firmness of the screw within the appliance, a universal Instron testing machine was used to record the forces released by each activation of the expander within the upper part of 10 clear modified twin blocks (MTBs) made from PETG and compare it with that released by 10 conventional twin blocks (CTBs).
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada.
Introduction: Validated models describing the biomechanics of tooth extraction are scarce. This study seeks to perform experimental and numerical characterization of vertical tooth extraction biomechanics in swine incisors with imposed vertical extraction loads. Imaging analysis related mechanical outcomes to tooth geometry and applied loading rate.