This paper presents a miniature manipulator under Cartesian control for minimally invasive transluminal endoscopic surgery. The manipulator had four degrees of freedom (DoFs) and a diameter of only 3.5 mm. The compact size of the manipulator allowed it to pass through the instrument channel of the endoscope, and its high dexterity allowed it to perform most of the operations in endoscopic surgery such as marking, grasping, hanging, etc. The implicit function relationship in the kinematics of the continuum manipulator was analyzed. By introducing the regression analysis method, the analytical form of the inverse kinematics was obtained. The distribution of singularities in the manipulator workspace was analyzed with emphasis. The presence of singularities made Cartesian mapping control between the primary side and secondary side impossible. By introducing the smoothing method of the joint trajectory, the discontinuity of the joint velocity at the singularity was avoided and the primary-secondary mapping under Cartesian control was realized. The trajectory-tracking experiment proved that the smoothness of the joint trajectory could make the manipulator smoothly pass through the singularity. The fixed-point marking experiment proved that the Cartesian control could improve the intuition of operation and the efficiency of task completion. Comprehensive performance experiments showed that the manipulator had enough dexterity to execute complex operations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9787422PMC
http://dx.doi.org/10.3390/mi13122171DOI Listing

Publication Analysis

Top Keywords

cartesian control
16
endoscopic surgery
12
miniature manipulator
8
control minimally
8
minimally invasive
8
invasive transluminal
8
transluminal endoscopic
8
joint trajectory
8
experiment proved
8
manipulator
7

Similar Publications

Improving human health and comfort in buildings requires efficient temperature regulation. Temperature control system has a significant contribution in minimizing the impact of climate change. Temperature control system is used in industry to control temperature.

View Article and Find Full Text PDF

Background: Given burdensome side-effects and long latency for efficacy with conventional agents, there is a continued need for generalised myasthenia gravis treatments that are safe and provide consistently sustained, long-term disease control. Nipocalimab, a neonatal Fc receptor blocker, was associated with dose-dependent reductions in total IgG and anti-acetylcholine receptor (AChR) antibodies and clinically meaningful improvements in the Myasthenia Gravis Activities of Daily Living (MG-ADL) scale in patients with generalised myasthenia gravis in a phase 2 study. We aimed to assess the safety and efficacy of nipocalimab in a phase 3 study.

View Article and Find Full Text PDF

Accelerated High-resolution T1- and T2-weighted Breast MRI with Deep Learning Super-resolution Reconstruction.

Acad Radiol

January 2025

Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (N.M., C.L., A.S., A.I., T.D., L.B., D.K., C.C.P., A.L., J.A.L.).

Rationale And Objectives: To assess the performance of an industry-developed deep learning (DL) algorithm to reconstruct low-resolution Cartesian T1-weighted dynamic contrast-enhanced (T1w) and T2-weighted turbo-spin-echo (T2w) sequences and compare them to standard sequences.

Materials And Methods: Female patients with indications for breast MRI were included in this prospective study. The study protocol at 1.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of Smart PDOs™ sutures for controlled silicon release and the Cartesian Technique™ for face lifting.
  • It involved both preclinical testing (using microscopy and spectroscopy) and clinical trials with 35 patients, focusing on improvements in skin turgidity and wrinkle reduction after treatment.
  • Results showed significant improvements in skin appearance and collagen quality, indicating that combining Smart PDOs™ with the Cartesian Technique™ is an effective method for enhancing skin rejuvenation.
View Article and Find Full Text PDF