Background: Computerized adventitious respiratory sounds (ARS), such as crackles and wheezes, have been poorly explored in bronchiectasis, especially their measurement properties. This study aimed to test the reliability and validity of ARS in bronchiectasis. Methods: Respiratory sounds were recorded twice at 4 chest locations on 2 assessment sessions (7 days apart) in people with bronchiectasis and daily sputum expectoration. The total number of crackles, number of wheezes and wheeze occupation rate (%) were the parameters extracted. Results: 28 participants (9 men; 62 ± 12 y) were included. Total number of crackles and wheezes showed moderate within-day (ICC 0.87, 95% CI 0.74−0.94; ICC 0.86, 95% CI 0.71−0.93) and between-day reliability (ICC 0.70, 95% CI 0.43−0.86; ICC 0.78, 95% CI 0.56−0.90) considering all chest locations and both respiratory phases; wheeze occupation rate showed moderate within-day reliability (ICC 0.86, 95% CI 0.71−0.93), but poor between-day reliability (ICC 0.71, 95% CI 0.33−0.87). Bland−Altman plots revealed no systematic bias, but wide limits of agreement, particularly in the between-days analysis. All ARS parameters correlated moderately with the amount of daily sputum expectoration (r > 0.4; p < 0.05). No other significant correlations were observed. Conclusion: ARS presented moderate reliability and were correlated with the daily sputum expectoration in bronchiectasis. The use of sequential measurements may be an option to achieve greater accuracy when ARS are used to monitor or assess the effects of physiotherapy interventions in this population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9787476PMC
http://dx.doi.org/10.3390/jcm11247509DOI Listing

Publication Analysis

Top Keywords

respiratory sounds
12
daily sputum
12
sputum expectoration
12
reliability icc
12
reliability validity
8
computerized adventitious
8
adventitious respiratory
8
people bronchiectasis
8
crackles wheezes
8
chest locations
8

Similar Publications

Introduction: The study was conducted to observe the effect of using relaxing sounds as a nonpharmacological intervention on anxiety levels and vital signs among patients who underwent extraction.

Materials And Methods: A randomized clinical trial was conducted, and patients with an indication of dental extraction, who were physically and mentally healthy, were invited to voluntarily participate in the study. Dental anxiety was assessed by measuring blood pressure, heart rates, and respiratory rates as well as with the help of the Modified Dental Anxiety Scale (MDAS) questionnaire before and after the procedure.

View Article and Find Full Text PDF

Background: Foreign body inhalation is rare in older children, often leading to underdiagnosis and delayed treatment. Most cases involve a single foreign body, but instances of multiple foreign bodies are exceedingly uncommon. This report presents a case of an elder child who inhaled two pen caps, emphasizing the need for clinical vigilance and thorough medical history collection.

View Article and Find Full Text PDF

Background: The integration of artificial intelligence (AI)-based pharmaceutical services in community pharmacy (CP) settings has the potential to enhance point-of-care services and improve informed patient access to healthcare. The Pneumoscope™, an innovative AI-powered digital stethoscope that analyses lung sounds to detect specific respiratory pathologies, could be a valuable tool for pharmacists in conducting respiratory screening. To understand how this device can be implemented in the healthcare system, this exploratory research aims to assess the acceptability of pharmacists and patients, and the pharmacists' readiness to use the Pneumoscope™ in CPs for respiratory disease management.

View Article and Find Full Text PDF

This report details a case study of a non-smoking 33-year-old female nurse who developed occupational asthma as an Inside Attendant (IA) in a hyperbaric chamber. The report analyzes the nurse's medical history, working environment, and potential causes. After beginning work in the hyperbaric chamber, an IA experienced respiratory symptoms, including coughing, wheezing, and fatigue.

View Article and Find Full Text PDF

Patients with pulmonary fibrosis (PF) often experience long waits before getting a correct diagnosis, and this delay in reaching specialized care is associated with increased mortality, regardless of the severity of the disease. Early diagnosis and timely treatment of PF can potentially extend life expectancy and maintain a better quality of life. Crackles present in the recorded lung sounds may be crucial for the early diagnosis of PF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!