Inferior vena cava (IVC) filters are posited to effect flow dynamics, causing turbulence, vascular remodeling and eventual thrombosis; however, minimal data exists evaluating hemodynamic effects of IVC filters in vivo. The purpose of this study was to determine differences in hemodynamic flow parameters acquired with two-dimension (2D)-perfusion angiography before and after IVC filter placement or retrieval. 2D-perfusion images were reconstructed retrospectively from digital subtraction angiography from a cohort of 37 patients (13F/24M) before and after filter placement (n = 18) or retrieval (n = 23). Average dwell time was 239.5 ± 132.1 days. Changes in the density per pixel per second within a region of interest (ROI) were used to calculate contrast arrival time (AT), time-to-peak (TTP), wash-in-rate (WIR), and mean transit time (MTT). Measurements were obtained superior to, inferior to, and within the filter. Differences in hemodynamic parameters before and after intervention were compared, as well as correlation between parameters versus filter dwell time. A P value with Bonferroni correction of <.004 was considered statistically significant. After placement, there was no difference in any 2D-perfusion variable. After retrieval, ROIs within and inferior to the filter showed a significantly shorter TTP (1.7 vs 1.4 s, P = .004; 1.5 vs 1.3 s, P = .001, respectively) and MTT (1.7 vs 1.4 s, P = .003; 1.5 vs 1.2 s, P = .002, respectively). Difference in variables showed no significant correlation when compared to dwell time. 2D-perfusion angiography is feasible to evaluate hemodynamic effects of IVC filters in vivo. TTP and MTT within and below the filter after retrieval were significantly changed, without apparent correlation to dwell time, suggesting a functional hemodynamic delay secondary to filter presence.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9771224 | PMC |
http://dx.doi.org/10.1097/MD.0000000000031600 | DOI Listing |
Med Phys
January 2025
Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Stockholm, Sweden.
Background: Modern reconstruction algorithms for computed tomography (CT) can exhibit nonlinear properties, including non-stationarity of noise and contrast dependence of both noise and spatial resolution. Model observers have been recommended as a tool for the task-based assessment of image quality (Samei E et al., Med Phys.
View Article and Find Full Text PDFObjective: The purpose of this study was to survey current physicians in Kentucky to evaluate their management of patients with substance use disorder (SUD), with a focus on the identification of their referral methods for linkage to SUD treatment and recovery support services.
Methods: A cross-sectional study was performed through a developed survey that was administered by e-mail to all 12,152 in-state physicians licensed in Kentucky; 524 responded. Addiction specialists, emergency physicians, and psychiatrists were categorized separately; family medicine and internal medicine (FM/IM) physicians were combined into one category; all of the other specialties were grouped into an "Other" category.
J Nat Resour Agric Ecosyst
January 2024
Office of Research and Development, USA Environmental Protection Agency, Research Triangle Park, North Carolina, USA.
J Vasc Interv Radiol
December 2024
Vascular Surgery, UF Health - Halifax Health, University of Florida, Daytona Beach, FL.
Purpose: Report 2-year outcomes from a prospective, multicenter, non-randomized, single-arm study designed to further assess the safety and effectiveness of the Celect and the Günther Tulip Vena Cava Filters.
Materials And Methods: The BLIND study enrolled patients requiring temporary or permanent IVC filter placement for the prevention of pulmonary embolism (PE). The primary effectiveness endpoint was the rate of technical placement success and 12-month freedom from new symptomatic PE while a filter was indwelling.
Ann Vasc Surg
December 2024
Department of Orthopedics, The Affiliated Changzhou Second People's Hospital of Nanjing Medical University, Changzhou, China, 213003. Electronic address:
Objective: To identify risk factors for loss to follow-up after inferior vena cava (IVC) filter placement in inpatients of other departments (IODs) and to determine whether a quality improvement project launched at our institution in April 2022 improved follow-up and filter retrieval rates in these patients.
Methods: Consecutive patients who underwent retrievable filter placement at our institution between March 2021 and March 2023 were included in this study. Patients were divided into preimprovement (before April 2022; n = 81) and postimprovement (after April 2022; n = 77) groups.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!