Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Using an magnetic resonance linear accelerator (MR-Linac) may improve the precision of visible tumor boosting with ultra-hypofractionation by accounting for daily positional changes in the target and organs at risk (OAR).
Patients And Methods: Fifteen patients with prostate cancer and an MR-detected dominant lesion were treated on the MR-Linac with stereotactic body radiation (SBRT) to 40 Gy in 5 fractions, boosting the gross tumor volume (GTV) to 45 Gy with daily adaptive planning. Imaging was acquired again after initial planning (verification scan), and immediately after treatment (post-treatment scan). Prior to beam-on, additional adjustments were made on the verification scan. Contours were retrospectively adjusted on verification and post-treatment scans, and the daily plan recalculated on these scans to estimate the true dose delivered.
Results: The median prostate D95% for plan 1, 2 and 3 was 40.3 Gy, 40.5 Gy and 40.3 Gy and DIL D95% was 45.7 Gy, 45.2 Gy and 44.6 Gy, respectively. Bladder filling was associated with reduced GTV coverage (p = 0.03, plan 1 vs 2) and prostate coverage (p = 0.03, plan 2 vs 3). The D0.035 cc constraint was exceeded on verification and post-treatment plans in 24 % and 33 % of fractions for the urethra, 31 % and 45 % for the bladder, and 35 % and 25 % for the rectum, respectively.
Conclusion: MR-Linac guided, daily adaptive SBRT with focal boosting of the GTV yields acceptable planned and delivered dosimetry. Adaptive planning with a MR-Linac may reliably deliver the prescribed dose to the intended tumor target.