Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hypothesis: Cochlear microphonic recorded at ear canal (CM-EC) can be a substitute for the one recorded at round window (CM-RW).
Background: Almost all clinics do not measure tone-burst evoked CM due to technical difficulty although it can provide more information than click evoked CM. Moreover, clinicians like the CM-EC more than that measured at CM-RW because CM-EC is non-invasive. There is difference between CM-RW and CM-EC, for example, CM-EC is less prominent than CM-RW, therefore, studying tone-burst evoked CM-EC and its relationship with CM-RW are highly significant and can promote the clinical application of CM-EC.
Method: Nine guinea pigs were randomly allocated into three groups, group 1 was not exposed to noise, called normal control. group 2 and group 3 were exposed to the low- (0.5-2 kHz) and high-frequency band-noise (6-8 kHz) at 120 dB SPL for 1 h, respectively. It was difficulty to record low-frequency CM due to severe environmental interruption, in current study the recording technology of tone-burst evoked CM was optimized so that tone-burst evoked CM was measured across full speech frequency (0.5-8 kHz) in the presence of normal hearing and noise induced hearing loss (NIHL).
Results: CM-RW and CM-EC were successfully recorded across speech frequency. Significant reduction in CM amplitude was observed at 0.5 and 2 kHz in group 2, at 6 and 8 kHz in group 3 as compared to group 1, < , indicating that CM amplitude was sensitive to band-noise exposure. Significant correlation between CM-RW and CM-EC was also verified, < .
Conclusion: CM-EC is a useful objective test for evaluation of hearing function; the result of current study supports the clinical application of non-invasive CM-EC.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9764817 | PMC |
http://dx.doi.org/10.1002/lio2.964 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!