Aim Of The Study: To compare the intraocular pressure (IOP) lowering effect and postoperative complications between primary augmented trabeculectomy and glaucoma drainage device (GDD) implantation as primary surgical intervention in patients with juvenile-onset open angle glaucoma (JOAG).

Patients And Methods: A retrospective review study involving 20 eyes that underwent primary augmented trabeculectomy with mitomycin (MMC) and 10 eyes GDD implantation in 3 tertiary centres in Malaysia between 1 January 2013 and 31 December 2019. They were followed up for at least 12 months postsurgical intervention. Intraocular pressure (IOP), number of topical IOP lowering medication and complications were evaluated at 1, 3, 6 and 12 months post-intervention. Based on the IOP, the success was divided into complete and partial success, and failure. IOP and postsurgical complications were compared using the Repetitive Measure Analysis of Variance (RM ANOVA) and the Pearson chi-square test.

Results: Both methods were effective in lowering the IOP. Eyes with primary augmented trabeculectomy have significant lower IOP compared to GDD implantation (p = 0.037). There was a higher incidence of postoperative hypotony (30%) in the trabeculectomy group. There was also a significant reduction of mean number of topical pressure-lowering drugs required postoperatively (p = 0.015). Complete success was achieved in 100% of eyes with trabeculectomy and 67% in GDD implantation (p = 0.047).

Conclusions: Primary augmented trabeculectomy and GDD implantation are good surgical options for the treatment of JOAG. Both methods provide IOP lowering at 1 year. However, trabeculectomy provides better pressure lowering, compared to GDD implantation in patients with JOAG.

Download full-text PDF

Source
http://dx.doi.org/10.31348/2022/29DOI Listing

Publication Analysis

Top Keywords

gdd implantation
24
primary augmented
16
augmented trabeculectomy
16
iop lowering
12
trabeculectomy
8
juvenile-onset open
8
open angle
8
angle glaucoma
8
intraocular pressure
8
iop
8

Similar Publications

Background/aims: Bleb characteristics in the area around the plate following glaucoma drainage device (GDD) surgery are difficult to evaluate on slit lamp examination. Ultrasound sonography could be used for more detailed visualisation. The aim of this study was to describe bleb configuration after PAUL glaucoma implant (PGI) surgery and evaluate the possible correlation with intraocular pressure (IOP) in order to derive new markers for evaluating GDD function.

View Article and Find Full Text PDF

Precis: Second trabeculectomy and glaucoma drainage device implantation offer similar success rates for juvenile open angle glaucoma after initial trabeculectomy failure. However, second trabeculectomies required fewer medications. A quarter of patients in both groups required a third operation after 2.

View Article and Find Full Text PDF

Glaucoma drainage devices (GDD) are used for patients with secondary glaucoma, such as uveitic or neovascular glaucoma, which is uncontrolled under local therapy. They are also used in patients with conjunctival scarring, for example after a previous vitrectomy or after unsuccessful previous glaucoma surgery, such as trabeculectomy. They are also a treatment option for congenital glaucoma, aphakic glaucoma or for the treatment of iridocorneoendothelial syndromes.

View Article and Find Full Text PDF

A New "Tube-in-tube" Method to Extend Glaucoma Drainage Devices Using Paul Glaucoma Implant.

J Curr Glaucoma Pract

October 2024

Department of Ophthalmology, Manchester Royal Eye Hospital, Manchester, England, United Kingdom.

Aim And Background: To describe a novel and uncomplicated technique of elongating the tubing of a glaucoma drainage device (GDD) sourced from a segment of the tube from a Paul® Glaucoma Implant (PGI).

Surgical Technique: Conjunctival and Tenon's peritomy are performed with relaxing incisions to expose the original tube. The original tube is then removed from the anterior chamber, and the original entry site is closed.

View Article and Find Full Text PDF

: We introduce a new surgical technique for inserting the eyePlate-300-a glaucoma drainage device (GDD). The flexibility of the eyePlate-300 allows for folding and insertion through a smaller conjunctival incision. The procedure is termed minimally invasive tube surgery (MITS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!