Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Point-of-care testing (POCT) of blood cell count (BCC) is an emerging approach that allows laypersons to identify and count whole blood cells through simple manipulation. To date, POCTs for BCC were mainly achieved by "stationary" images through blood smears or single-laity arranged cells in the microwell, making it difficult to obtain statistically sufficient numbers of cells. In this work, we present a fully integrated POCT device solely using "in-flow" imaging of 3 μL fingertip whole blood for improved identification and counting accuracy of BCC analysis. A miniaturized magnetic stirring module was integrated to maintain the temporal stability of cell concentration. A relatively high throughput (∼8000 cells/min) with a 30-fold dilution ratio of whole blood can be tested for as long as 1 h to examine sufficient numbers of cells, and the subclass cell concentration keeps constant. To improve the identification accuracy, multi-frame "in-flow" imaging was used to track the cell motion trails with multi-angle morphology analysis. This proof-of-concept was then validated with healthy whole blood samples and 75 cases of clinical patients with abnormal concentrations of red blood cells (RBCs), white blood cells (WBCs), and platelets (PLT). The average precision (AP) value of WBCs identification was improved from 0.8622 to 0.9934 using the multi-frame analysis method. And the high fitting degrees (>0.98) between our POCT device and the commercial clinical equipment indicated good agreement. This POCT device is user-friendly and cost-effective, making it a potential tool for diagnosing abnormal blood cell morphology or concentration in the field setting.