A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical Performance of a Hydrophobic Acrylic Diffractive Trifocal Intraocular Lens in a Japanese Population. | LitMetric

Introduction: In this study, clinical performance of a hydrophobic acrylic diffractive trifocal intraocular lens (IOL) with double C-loop haptics was evaluated in Japanese cataract eyes.

Methods: Twenty-three patients had bilateral cataract surgery with the implantation of a trifocal IOL with double C-loop haptics. Postoperative examinations at 6 months included assessing uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA) at 5 m, uncorrected intermediate visual acuity (UIVA), distance-corrected intermediate visual acuity (DCIVA) at 80 cm, uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) at 40 cm. Binocular defocus, contrast sensitivity, spectacle independence, symptoms of photic phenomena and quality of vision (QOV) were also observed.

Results: Twenty-three patients received 46 IOLs binocularly. Manifest refraction spherical equivalent was - 0.227 ± 0.385 D (mean ± standard deviation) at 6 months postoperatively. Binocular UDVA, binocular UIVA and binocular UNVA were - 0.101 ± 0.065, - 0.021 ± 0.079 and 0.022 ± 0.095 logMAR units, respectively. Binocular CDVA, binocular DCIVA and binocular DCNVA were - 0.151 ± 0.044, - 0.042 ± 0.067 and - 0.011 ± 0.080 logMAR, respectively. Binocular CDVA of 0.00 logMAR or better was obtained in the defocus from - 3.0 D until + 0.5 D. Only 8.7% of patients required the use of spectacles postoperatively. There were no symptoms of glare, halo and light disturbance in 78.3%, 56.5% and 69.6% of patients, respectively. QOV scores significantly improved postoperatively (P < 0.0001).

Conclusion: The hydrophobic acrylic trifocal IOL with double C-loop haptics provides good visual performance at all distances and produces high spectacle independence rate and patient satisfaction.

Trial Registration Number: NCT04699266 (Clinicaltrials.gov).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9768760PMC
http://dx.doi.org/10.1007/s40123-022-00634-4DOI Listing

Publication Analysis

Top Keywords

visual acuity
24
clinical performance
8
performance hydrophobic
8
hydrophobic acrylic
8
acrylic diffractive
8
diffractive trifocal
8
trifocal intraocular
8
intraocular lens
8
iol double
8
double c-loop
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!