Influence of the biomechanical environment on the femoral stem insertion and vibrational behavior: a 3-D finite element study.

Biomech Model Mechanobiol

CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010, Créteil, France.

Published: April 2023

AI Article Synopsis

  • * It investigates the relationship between resonance frequencies of the bone-implant system and the stability of the femoral stem, focusing on variables such as interference fit, bone stiffness, and friction during implant insertion.
  • * Results indicate a trade-off between maximizing bone-implant contact and maintaining adequate pull-out force; vibration analysis methods can help optimize implant stability for different patients and surgical settings.

Article Abstract

The long-term success of cementless surgery strongly depends on the implant primary stability. The femoral stem initial fixation relies on multiple geometrical and material factors, but their influence on the biomechanical phenomena occurring during the implant insertion is still poorly understood, as they are difficult to quantify in vivo. The aim of the present study is to evaluate the relationship between the resonance frequencies of the bone-implant-ancillary system and the stability of the femoral stem under various biomechanical environments. The interference fit IF, the trabecular bone Young's modulus [Formula: see text] and the bone-implant contact friction coefficient [Formula: see text] are varied to investigate their influence on the implant insertion phenomena and on the system vibration behavior. The results exhibit for all the configurations, a nonlinear increase in the bone-implant contact throughout femoral stem insertion, until the proximal contact is reached. While the pull-out force increases with [Formula: see text], IF and [Formula: see text], the bone-implant contact ratio decreases, which shows that a compromise on the set of parameters could be found in order to achieve the largest bone-implant contact while maintaining sufficient pull-out force. The modal analysis on the range [2-7] kHz shows that the resonance frequencies of the bone-implant-ancillary system increase with the bone-implant contact ratio and the trabecular bone Young's modulus, with a sensitivity that varies over the modes. Both the pull-out forces and the vibration behavior are consistent with previous experimental studies. This study demonstrates the potential of using vibration methods to guide the surgeons for optimizing implant stability in various patients and surgical configurations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10237-022-01667-1DOI Listing

Publication Analysis

Top Keywords

bone-implant contact
20
femoral stem
16
[formula text]
16
influence biomechanical
8
stem insertion
8
stability femoral
8
implant insertion
8
resonance frequencies
8
frequencies bone-implant-ancillary
8
bone-implant-ancillary system
8

Similar Publications

Purpose: Biomimetic agents are being researched for their potential to stimulate bone formation and boost bone-implant contact. The objective of this study was to assess how osseointegration of dental implants is impacted by platelet-rich fibrin.

Materials And Methods: The present study was a randomized clinical trial with a split mouth design.

View Article and Find Full Text PDF

Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing.

ACS Omega

December 2024

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration & National Clinical Research Center for Oral Diseases & Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, Shaanxi, P. R. China.

Metal 3D printing has been used in the manufacturing of dental implants. Its technical advantages include high material utilization and the capacity to form arbitrarily complex structures. However, 3D printing alone is insufficient for manufacturing two-stage titanium implants due to the limited precision in printing titanium alloy parts.

View Article and Find Full Text PDF

Background And Objective: Dental implant therapy faces challenges in patients with Type 1 and Type 2 Diabetes Mellitus (T1DM and T2DM) due to adverse effects on bone metabolism and immune response. Despite advancements, diabetic patients face higher risks of peri-implantitis and compromised osseointegration. This review assesses the impact of anti-diabetic medications on implant outcomes, offering insights to bridge the gap between animal studies and clinical practice.

View Article and Find Full Text PDF

Aim: We aimed to investigate whether α-ketoglutarate (AKG) can promote autophagic activity under a peri-implant condition to enhance the osseointegration of dental implant in rats with osteoporosis (OP).

Methods: Con, Model and AKG groups were established for the random allocation of thirty rats ( = 10). Their bone metabolism indicators were measured.

View Article and Find Full Text PDF

Osteomyelitis with a high recurrence rate. Timely-prevention can avoid severe consequence and death. However, conventional drug response-release has the disadvantages of unnecessary release and waste, causing ineffective prevention.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!