Organ dose calculator for diagnostic nuclear medicine patients based on the ICRP reference voxel phantoms and biokinetic models.

Biomed Phys Eng Express

Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, United States of America.

Published: December 2022

The exponential growth in the use of nuclear medicine procedures represents a general radiation safety concern and stresses the need to monitor exposure levels and radiation-related long term health effects in NM patients. In the current study, following our previous work on NCINM version 1 based on the UF/NCI hybrid phantom series, we calculated a comprehensive library of S values using the ICRP reference pediatric and adult voxel phantoms and established a library of biokinetic data from multiple ICRP Publications, which were then implemented into NCINM version 2. We calculated S values in two steps: calculation of specific absorbed fraction (SAF) using a Monte Carlo radiation transport code combined with the twelve ICRP pediatric and adult voxel phantoms for a number of combinations of source and target region pairs; derivation of S values from the SAFs using the ICRP nuclear decay data. We also adjusted the biokinetic data of 105 radiopharmaceuticals from multiple ICRP publications to match the anatomical description of the ICRP voxel phantoms. Finally, we integrated the ICRP phantom-based S values and adjusted biokinetic data into NCINM version 2. The ratios of cross-fire SAFs from NCINM 2 to NCINM 1 for the adult phantoms varied widely from 0.26 to 5.94 (mean = 1.24, IQR = 0.77-1.55) whereas the ratios for the pediatric phantoms ranged from 0.64 to 1.47 (mean = 1.01, IQR = 0.98-1.03). The ratios of absorbed dose coefficients from NCINM 2 over those from ICRP publications widely varied from 0.43 (colon forTc-ECD) to 2.57 (active marrow forTc-MAG3). NCINM 2.0 should be useful for dosimetrists and medical physicists to more accurately estimate organ doses for various nuclear medicine procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10829005PMC
http://dx.doi.org/10.1088/2057-1976/aca543DOI Listing

Publication Analysis

Top Keywords

voxel phantoms
16
nuclear medicine
12
ncinm version
12
biokinetic data
12
icrp publications
12
icrp
9
icrp reference
8
medicine procedures
8
pediatric adult
8
adult voxel
8

Similar Publications

Background: MRI offers quantification of proton density fat fraction (PDFF) and tissue characteristics with T1 mapping. The influence of age, sex, and the potential confounding effects of fat on T1 values in skeletal muscle in healthy adults are insufficiently known.

Purpose: To determine the accuracy and repeatability of a saturation-recovery chemical-shift encoded multiparametric approach (SR-CSE) for quantification of T1 and muscle fat content, and establish normative values (age, sex) from a healthy cohort.

View Article and Find Full Text PDF

Heterogeneous head phantom for validating treatment planning system in boron neutron capture therapy.

Appl Radiat Isot

January 2025

Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan; Nuclear Science and Technology Development Center, National Tsing Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan. Electronic address:

In clinical boron neutron capture therapy (BNCT), the distribution of dose to a heterogeneous medium that is predicted by a treatment planning system (TPS) should be experimentally validated. A head phantom specifically developed for this purpose is described and demonstrated herein. The cylindrical phantom exhibits distinct regions made from four materials (polymethyl methacrylate, calcium phosphate, air, and boric acid) to approximate a head structure with explicitly defined skin, skull, and brain tissue with a cavity and tumor within.

View Article and Find Full Text PDF

Background: With increasing evidence supporting three-dimensional (3D) automated breast (AB) ultrasound (US) for supplemental screening of breast cancer in increased-risk populations, including those with dense breasts and in limited-resource settings, there is an interest in developing more robust, cost-effective, and high-resolution 3DUS imaging techniques. Compared with specialized ABUS systems, our previously developed point-of-care 3D ABUS system addresses these needs and is compatible with any conventional US transducer, which offers a cost-effective solution and improved availability in clinical practice. While conventional US transducers have high in-plane resolution (axial and lateral), their out-of-plane resolution is constrained by the poor intrinsic elevational US resolution.

View Article and Find Full Text PDF

Spatially constrained hyperpolarized 13C MRI pharmacokinetic rate constant map estimation using a digital brain phantom and a U-Net.

J Magn Reson

January 2025

UC Berkeley - UCSF Graduate Program in Bioengineering, 1700 4th St, San Francisco, CA 94158, USA; Radiology and Biomedical Imaging, University of California, San Francisco, 1700 4th St, San Francisco, CA 94158, USA.

Fitting rate constants to Hyperpolarized [1-C]Pyruvate (HP C13) MRI data is a promising approach for quantifying metabolism in vivo. Current methods typically fit each voxel of the dataset using a least-squares objective. With these methods, each voxel is considered independently, and the spatial relationships are not considered during fitting.

View Article and Find Full Text PDF

Self-supervised parametric map estimation for multiplexed PET with a deep image prior.

Phys Med Biol

January 2025

The Division of Imaging Sciences and Biomedical Engineering, King's College London, 5th Floor Becket House, London, SE1 7EH, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND.

Multiplexed positron emission tomography (mPET) imaging allows simultaneous observation of physiological and pathological information from multiple tracers in a single PET scan. Although supervised deep learning has demonstrated superior performance in mPET image separation compared to purely model-based methods, acquiring large amounts of paired single-tracer data and multi-tracer data for training poses a practical challenge and needs extended scan durations for patients. In addition, the generalisation ability of the supervised learning framework is a concern, as the patient being scanned and their tracer kinetics may potentially fall outside the training distribution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!