Consumer-grade heart rate (HR) sensors including chest straps, wrist-worn watches and rings have become very popular in recent years for tracking individual physiological state, training for sports and even measuring stress levels and emotional changes. While the majority of these consumer sensors are not medical devices, they can still offer insights for consumers and researchers if used correctly taking into account their limitations. Multiple previous studies have been done using a large variety of consumer sensors including Polar® devices, Apple® watches, and Fitbit® wrist bands. The vast majority of prior studies have been done in laboratory settings where collecting data is relatively straightforward. However, using consumer sensors in naturalistic settings that present significant challenges, including noise artefacts and missing data, has not been as extensively investigated. Additionally, the majority of prior studies focused on wrist-worn optical HR sensors. Arm-worn sensors have not been extensively investigated either. In the present study, we validate HR measurements obtained with an arm-worn optical sensor (Polar OH1) against those obtained with a chest-strap electrical sensor (Polar H10) from 16 participants over a 2-week study period in naturalistic settings. We also investigated the impact of physical activity measured with 3-D accelerometers embedded in the H10 chest strap and OH1 armband sensors on the agreement between the two sensors. Overall, we find that the arm-worn optical Polar OH1 sensor provides a good estimate of HR (Pearson r = 0.90, p <0.01). Filtering the signal that corresponds to physical activity further improves the HR estimates but only slightly (Pearson r = 0.91, p <0.01). Based on these preliminary findings, we conclude that the arm-worn Polar OH1 sensor provides usable HR measurements in daily living conditions, with some caveats discussed in the paper.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830591 | PMC |
Mikrochim Acta
January 2025
Department of Analytical Chemistry, Faculty of Pharmacy, "Iuliu Hațieganu" University of Medicine and Pharmacy, 4 Pasteur Street, 400349, Cluj-Napoca, Romania.
A label-free, flexible, and disposable aptasensor was designed for the rapid on-site detection of vancomycin (VAN) levels. The electrochemical sensor was based on lab-printed carbon electrodes (C-PE) enriched with cauliflower-shaped gold nanostructures (AuNSs), on which VAN-specific aptamers were immobilized as biorecognition elements and short-chain thiols as blocking agents. The AuNSs, characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM), enhanced the electrochemical properties of the platform and the aptamer immobilization active sites.
View Article and Find Full Text PDFMol Divers
January 2025
Key Laboratory for Macromolecular Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710119, People's Republic of China.
Molecular Property Prediction (MPP) is a fundamental task in important research fields such as chemistry, materials, biology, and medicine, where traditional computational chemistry methods based on quantum mechanics often consume substantial time and computing power. In recent years, machine learning has been increasingly used in computational chemistry, in which graph neural networks have shown good performance in molecular property prediction tasks, but they have some limitations in terms of generalizability, interpretability, and certainty. In order to address the above challenges, a Multiscale Molecular Structural Neural Network (MMSNet) is proposed in this paper, which obtains rich multiscale molecular representations through the information fusion between bonded and non-bonded "message passing" structures at the atomic scale and spatial feature information "encoder-decoder" structures at the molecular scale; a multi-level attention mechanism is introduced on the basis of theoretical analysis of molecular mechanics in order to enhance the model's interpretability; the prediction results of MMSNet are used as label values and clustered in the molecular library by the K-NN (K-Nearest Neighbors) algorithm to reverse match the spatial structure of the molecules, and the certainty of the model is quantified by comparing virtual screening results across different K-values.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Research Centre for Biomedical Engineering, City St George's, University of London, London, EC1V 0HB, UK.
Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO measurement in consumer wearables that utilise reflectance pulse oximeters.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 611731, China.
Lithium-ion batteries represent a significant component of the field of energy storage, with a diverse range of applications in consumer electronics, portable devices, and numerous other fields. In view of the growing concerns about the safety of batteries, it is of the utmost importance to develop a sensor that is capable of accurately monitoring the internal temperature of lithium-ion batteries. External sensors are subject to the necessity for additional space and ancillary equipment.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Institute of Physics, University of Tartu, EE-50411 Tartu, Estonia.
Low-power gas sensors that can be used in IoT (Internet of Things) systems, consumer devices, and point-of-care devices will enable new applications in environmental monitoring and health protection. We fabricated a monolithic chemiresistive gas sensor by integrating a micro-lightplate with a 2D sensing material composed of single-layer graphene and monolayer-thick TiO. Applying ultraviolet (380 nm) light with quantum energy above the TiO bandgap effectively enhanced the sensor responses.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!