The rapid ultrasound for shock and hypotension (RUSH) protocol is a useful tool used in the emergency department (ED) when addressing the severity and etiology of shock. It was designed to be performed in under two minutes with evaluation of the pump (heart), tank (inferior vena cava, thoracic and abdominal compartments) and the pipes (large arteries and veins). However, its application or one similar should extend beyond the ED and into the hospital floor. Here we present an 80-year-old gentleman with a history of atrial fibrillation (A-Fib) on anticoagulation who arrived at the ED due to an episode of pre-syncope just prior to arrival. Initial EKG is concerning for A-Fib with rapid ventricular response (RVR) with a rate in the 130s. After fluid resuscitation patient improved and he was admitted to the telemetry floor for further cardiac workup and cardiology consultation. While waiting for a room in the ED, patient became hypotensive, diaphoretic and pale. After complaining of lower abdominal pain, the ED physician performed a RUSH which showed an abdominal aorta of 8 cm concerning for dissection. Diagnosis was confirmed with CT angiography of the abdomen and he was taken to the OR with successful repair of the abdominal aortic aneurysm (AAA). Patient made meaningful recovery and was discharged to in-patient rehab. The patient described in this vignette was delayed in the ED due to lack of beds on the floor. This allowed for quick ultrasound work-up by the ED physician which led to immediate recognition of the AAA and immediate response by the vascular surgery team. Should this patient have been on the hospital floor, it is unclear if such prompt steps would have occurred prior to patient's further hemodynamic demise.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9754670PMC
http://dx.doi.org/10.7759/cureus.32565DOI Listing

Publication Analysis

Top Keywords

rapid ultrasound
8
ultrasound shock
8
shock hypotension
8
hypotension rush
8
rush protocol
8
hospital floor
8
abdominal
5
patient
5
rushing diagnosis
4
diagnosis aortic
4

Similar Publications

Objectives: To assess the ability of a previously trained deep-learning algorithm to identify the presence of inflammation on MRI of sacroiliac joints (SIJ) in a large external validation set of patients with axial spondyloarthritis (axSpA).

Methods: Baseline SIJ MRI scans were collected from two prospective randomised controlled trials in patients with non-radiographic (nr-) and radiographic (r-) axSpA (RAPID-axSpA: NCT01087762 and C-OPTIMISE: NCT02505542) and were centrally evaluated by two expert readers (and adjudicator in case of disagreement) for the presence of inflammation by the 2009 Assessment of SpondyloArthritis International Society (ASAS) definition. Scans were processed by the deep-learning algorithm, blinded to clinical information and central expert readings.

View Article and Find Full Text PDF

Objectives: To facilitate the stratification of patients with osteoarthritis (OA) for new treatment development and clinical trial recruitment, we created an automated machine learning (autoML) tool predicting the rapid progression of knee OA over a 2-year period.

Methods: We developed autoML models integrating clinical, biochemical, X-ray and MRI data. Using two data sets within the OA Initiative-the Foundation for the National Institutes of Health OA Biomarker Consortium for training and hold-out validation, and the Pivotal Osteoarthritis Initiative MRI Analyses study for external validation-we employed two distinct definitions of clinical outcomes: Multiclass (categorising OA progression into pain and/or radiographic) and binary.

View Article and Find Full Text PDF

Increased use of arthroscopically assisted techniques for the treatment of ankle fractures has been reported. Despite their rapid development, there is only one systematic review regarding arthroscopically assisted treatment of ankle fractures, in which, however, only malleolar fracture studies are included. Various other types of ankle fractures have also been treated with arthroscopically assisted procedures.

View Article and Find Full Text PDF

A Force-Sensor-Less Approach for Rapid Young's Modulus Identification of Heterogeneous Soft Tissue.

J Biomech Eng

January 2025

State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanical Engineering, Zhejiang University, Hangzhou, 315000, China.

Due to individual differences, accurate identification of tissue elastic parameters is essential for biomechanical modeling in surgical guidance for hepatic venous injections. This paper aims to acquire the absolute Young's modulus of heterogeneous soft tissues during endoscopic surgery with 2D ultrasound images. First, we introduced a force-sensor-less approach that utilizes a pre-calibrated soft patch with a known Young's modulus and its ultrasound images to calculate the external forces exerted by the probe on the tissue.

View Article and Find Full Text PDF

Wave-CAIPI Multiparameter MR Imaging in Neurology.

NMR Biomed

March 2025

Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.

In clinical practice, particularly in neurology assessments, imaging multiparametric MR images with a single-sequence scan is often limited by either insufficient imaging contrast or the constraints of accelerated imaging techniques. A novel single scan 3D imaging method, incorporating Wave-CAIPI and MULTIPLEX technologies and named WAMP, has been developed for rapid and comprehensive parametric imaging in clinical diagnostic applications. Featuring a hybrid design that includes wave encoding, the CAIPIRINHA sampling pattern, dual time of repetition (TR), dual flip angle (FA), multiecho, and optional flow modulation, the WAMP method captures information on RF B1t fields, proton density (PD), T1, susceptibility, and blood flow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!