In this study, we tested the performance of the Sysmex UF-5000 system to detect yeast-like cell (YLC) counting to screen for candiduria. Urine samples were screened for leukocyte and yeast amount by flow cytometry and results were compared with fungal culture results. A total of 56,749 urine samples were enrolled in this study. Urine culture and urinalysis of YLC data were used to evaluate the performance of YLC in diagnosing candiduria. Different cut-off values (YLC. 5, 10, 20, 50, 100/μl) were evaluated. Youden index was used to determine the ideal cut-off value, and the highest was 0.95 with 5 YLC/μl. When the cut-off value for YLC is 5 cells/μl, 95.15% of the samples were "negative" with flow cytometry and culture (NPV:100%). In conclusion, detection of YLC by flow cytometer (Sysmex UF-5000) can be a rapid alternative method to exclude candiduria prior to urine culture.
Download full-text PDF |
Source |
---|
Clin Chem Lab Med
January 2025
117303 Graduate Program in Health Sciences, Federal University of Health Sciences of Porto Alegre, Porto Alegre, Brazil.
Objectives: To evaluate urinalysis parameters useful for identifying mixed cultures in urine culture using an automated urinary particle analyzer to assess quality indicators (QIs) for urine sample contamination.
Methods: A retrospective observational cross-sectional study was conducted with 2,527 urine samples from patients of a quaternary hospital in Brazil. Urine samples were processed simultaneously in Sysmex UF-5000 flow cytometry analyzer (urinalysis) and MALDI-TOF (culture).
Clin Chem Lab Med
September 2024
National Clinical Research Center for Laboratory Medicine, Department of Laboratory Medicine, 159407 The First Hospital of China Medical University, Shenyang, Liaoning, P.R. China.
Objectives: Atypical cells (Atyp.C), as a new parameter determined by an automated urine analyzer, can be suspected of being malignant tumor cells. We evaluated the extent to which the Atyp.
View Article and Find Full Text PDFPLoS One
June 2024
Clinical Laboratory, Children's Hospital Affiliated to Shandong University, Jinan, China.
Background: A rapid screening test for urinary tract infections (UTIs) in children is needed to avoid unnecessary cultures and provide prompt reports to make appropriate clinical decisions. We have evaluated for the first time the performance of the Sysmex UF-5000 flow cytometer as a screening tool for UTIs in children.
Methods: This study included 4445 pediatric patients, with urinary sediment and urine culture data collected from January 2020 to September 2023.
Sci Rep
June 2024
Department of Clinical Laboratory, Second Hospital, Xi'an Jiaotong University, Xi'an, 710004, China.
Bladder carcinoma (BC) accounts for > 90% of all urothelial cancers. Pathological diagnosis through cytoscopic biopsy is the gold standard, whereas non-invasive diagnostic tools remain lacking. The "Atyp.
View Article and Find Full Text PDFJ Microbiol Methods
May 2024
Department of Urology, Graduate School of Medicine, Gifu University, 1-1 Yanagido, Gifu City, Gifu 501-1193, Japan; Department of Urology, Kizawa Memorial Hospital, 590 Shimokobi, Kobicho, Minokamo, Gifu 505-8503, Japan.
Several types of fastidious bacteria can cause tract infections. We evaluated the performance of counting fastidious bacteria using a Fully Automated Urine Particle Analyzer UF-5000. The results showed that UF-5000 counts fastidious bacteria in urine without the need for culture using measurement principles based on flow cytometry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!