Background And Objectives: It remains unclear whether the use of the stylet slow-pull (SP) and wet suction (WS) can improve the yield of endoscopic ultrasound-guided fine-needle biopsy compared to standard suction (SS). The aim of this study was to compare the diagnostic efficacy of the three sampling techniques when using 25G ProCore needles for solid pancreatic lesions.
Materials And Methods: This multicenter single-blind randomized crossover superiority trial enrolled patients with solid pancreatic lesions (n = 300) from four digestive endoscopic centers in China. All three sampling techniques were performed on each patient using a 25G ProCore needle in a randomized sequence. The diagnostic efficacy, the specimen yield, and quality of each technique, the overall technical success rate and diagnostic yield of the 25G ProCore needle, and rate of adverse events were evaluated.
Results: A total of 291 patients were analyzed. No significant difference was found in diagnostic efficiency among the three techniques (sensitivity, 82.14% vs. 75.00% vs. 77.86, P = 0.1186; accuracy, 82.82% vs. 75.95% vs. 78.69%, P = 0.1212). The SP had an inferior tissue integrity compared to the SS and WS techniques (71.82% vs. 62.55% vs. 69.76%, P = 0.0096). There was no significant difference in the degree of blood contamination among the three groups (P = 0.2079). After three passes, the overall sensitivity was 93.93%, and the accuracy was 94.16%.
Conclusions: SS and WS techniques are better choices than SP technique for 25G ProCore needle, for they could provide higher specimen adequacy without increasing the amount of blood contamination. The 25G ProCore needle can provide a satisfactory diagnostic yield for solid pancreatic lesions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921982 | PMC |
http://dx.doi.org/10.4103/EUS-D-21-00256 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!