AI Article Synopsis

Article Abstract

Objectives: The aim of this study was to estimate the seroprevalence of anti-SARS-CoV-2 antibodies using the SARS-CoV-2 antibody test in a university population. Capillary blood and plasma samples were compared and correlated with symptomatology to establish rapid treatment processes and develop a public health strategy within the community.

Study Design: Descriptive study of seroprevalence of anti-SARS-CoV-2 antibodies in a university population.

Methods: Standardised and validated laboratory serological tests were used to assess the immune response detected in capillary blood and plasma samples. In this study, 280 participants from the University Colegio Mayor de Antioquia in the Municipality of Medellín, Colombia, were tested for SARS-CoV-2 antibodies in capillary blood and plasma samples between November 2020 and January 2021.

Results: In total, 29 (11.2%) individuals had positive results for anti-SARS-CoV-2 antibodies (IgG/IgM); 28 (96.6%) had positive results in plasma samples and 11 (37.9%) in capillary blood samples. The two tests were compared, and the overall sensitivity and specificity of capillary vs plasma samples was 36.7% and 99.6%, respectively.

Conclusions: Anti-SARS-CoV-2 antibodies (IgG/IgM) can be used to estimate the seroprevalence in populations, including immunity by vaccination; however, capillary blood samples should not be used to detect previous infection as they provide low sensitivity compared to plasma samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9751005PMC
http://dx.doi.org/10.1016/j.puhip.2022.100347DOI Listing

Publication Analysis

Top Keywords

plasma samples
28
capillary blood
24
blood plasma
16
anti-sars-cov-2 antibodies
16
samples
9
sars-cov-2 antibodies
8
university population
8
medellín colombia
8
estimate seroprevalence
8
seroprevalence anti-sars-cov-2
8

Similar Publications

Background And Objectives: Despite the absence of acute lesion activity in multiple sclerosis (MS), chronic neurodegeneration continues to progress, and a potential underlying mechanism could be the kynurenine pathway (KP). Prolonged activation of the KP from chronic inflammation is known to exacerbate the progression of neurodegenerative diseases through the production of neurotoxic metabolites. Among the 8 KP metabolites, six of them, namely kynurenine (KYN), 3-hydroxylkynurenine (3HK), anthranilic acid (AA), kynurenic acid (KYNA), and quinolinic acid (QUIN), have been associated with neurodegeneration.

View Article and Find Full Text PDF

Background: Lowering barometric pressure (LP) can exacerbate neuropathic pain. However, animal studies in this field are limited to a few conditions. Furthermore, although sympathetic involvement has been reported as a possible mechanism, whether the sympathetic nervous system is involved in the hypothalamic-pituitary-adrenal (HPA) axis remains unknown.

View Article and Find Full Text PDF

In recent years, despite significant advances in preconcentration and preparation techniques that have led to efficient recovery and accurate measurement of target compounds. There is still a need to develop adsorbents with unique and efficient features such as high pore volume and surface area, reactivity, easy synthesis, low toxicity, and compatibility with the environment, which increase the adsorption capacity and increase extraction efficiency. Semiconductor nanocrystals called quantum dots (QDs) with a size of less than 10 nm are three-dimensional nanoparticles with a spherical, rod, or disc structure that have significant potential in extraction as adsorbents due to their excellent properties such as low toxicity, reactivity, environmental friendliness, and hydrophilic and hydrophobic interactions.

View Article and Find Full Text PDF

Objectives: The aim of this study was to establish an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the detection of osimertinib in rat plasma, lung and brain tissues.

Methods: Forty-eight rats were randomly divided into an experimental group (receiving osimertinib at doses of 5, 8, and 10 mg/kg) and a control group. After continuous intragastric administration for 15 days, samples of blood, lung, and brain tissue were collected.

View Article and Find Full Text PDF

Introduction: We evaluated the diagnostic performance of two commercial plasma p-tau217 immunoassays compared to cerebrospinal fluid (CSF) testing and neuropathology.

Methods: One hundred and seventy plasma samples from the University of British Columbia Hospital Clinic for Alzheimer's (AD) and Related Disorders were analyzed for p-tau217 using Fujirebio and ALZpath assays. Decision points were determined using CSF testing and autopsy findings as the standard.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!