A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel Hybrid Adsorption-Electrodialysis (AdED) System for Removal of Boron from Geothermal Brine. | LitMetric

A novel hybrid adsorption-electrodialysis (AdED) system to remove environmentally harmful boron from geothermal brine was designed and effective operating parameters such as pH, voltage, and flow rate were studied. A cellulose-based adsorbent was synthesized from glycidyl methacrylate (GMA) grafted cellulose and modified with a boron selective n-methyl-d-glucamine (NMDG) group and characterized with SEM-EDX, FT-IR, and TGA analyses. Batch adsorption studies revealed that cellulose-based adsorbent showed a remarkable boron removal capacity (19.29 mg/g), a wide stable operating pH range (2-10), and an adsorption process that followed the Freundlich isotherm ( = 0.95) and pseudo-second-order kinetics ( = 0.99). In the hybrid AdED system, the optimum operating parameters for boron removal were found to be a pH of 10, a voltage of 10 V, a flow rate of 100 mL/min, and an adsorbent dosage of 4 g/L. The presence of the adsorbent in the hybrid system increased boron removal from real geothermal brine (containing 199 ppm boron) from 7.2% to 73.3%. The results indicate that the designed AdED system performs better than bare electrodialysis for boron removal from ion-rich real geothermal brine while utilizing environmentally friendly cellulose-based adsorbent.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9753525PMC
http://dx.doi.org/10.1021/acsomega.2c06046DOI Listing

Publication Analysis

Top Keywords

aded system
16
geothermal brine
16
boron removal
16
cellulose-based adsorbent
12
novel hybrid
8
hybrid adsorption-electrodialysis
8
adsorption-electrodialysis aded
8
boron
8
boron geothermal
8
operating parameters
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!