Background: Airborne biologic particles (ABPs) can be measured intraoperatively to evaluate operating room (OR) sterility. Our study examines the role of OR size on air quality and ABP count in primary total hip arthroplasty (THA).
Methods: We analyzed primary THA procedures done within 2 ORs measuring 278 ft and 501 ft at a single academic institution from April 2019 to June 2020. Temperature, humidity, and ABP count per minute were recorded with a particle counter intraoperatively and cross-referenced with surgical data from the electronic health records using procedure start and end times. Descriptive statistics were used to evaluate differences in variables. P-values were calculated using t-test and chi-squared test.
Results: A total of 116 primary THA cases were included: 18 (15.5%) in the "small" OR and 98 (84.5%) in the "large" OR. Between-group comparisons revealed significant differences in temperature (small OR: 20.3 ± 1.23 C versus large OR: 19.1 ± 0.85 C, P < .0001) and relative humidity (small OR: 41.1 ± 7.24 versus large OR: 46.9 ± 7.56, P < .001). Significant percent decreases in ABP rates for particles measuring 2.5 um (-125.0%, P = .0032), 5.0 um (-245.0%, P = .00078), and 10.0 um (-413.9%, P = .0021) were found in the large OR. Average time spent in the OR was significantly longer in the large OR (174 ± 33 minutes) compared to the small OR (151 ± 14 minutes) (P = .00083).
Conclusion: Temperature and humidity differences and significantly lower ABP counts were found in the large compared to the small OR despite longer average time spent in the large OR, suggesting the filtration system encounters less particle burden in larger rooms. Further research is needed to determine the impact this may have on infection rates.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2022.12.011 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!