Background And Objective: Acquiring accurate and reliable health information using a PPG signal in wearable devices requires suppressing motion artifacts. This paper presents a method based on the Fractional Fourier transform (FrFT) to effectively suppress the motion artifacts in a Photoplethysmogram (PPG) signal for an accurate estimation of heart rate (HR).

Methods: By analyzing various PPG signals recorded under various physiological conditions and sampling frequencies, the proposed work determines an optimal value of the fractional order of the proposed FrFT. The proposed FrFT-based algorithm separates the motion artifacts component from the acquired PPG signal. Finally, the HR estimation accuracy during the strong motion artifact-affected windows is improved using a post-processing technique. The efficacy of the proposed method is evaluated by computing the root mean square error (RMSE).

Results: The performance of the proposed algorithm is compared with methods in recent studies using test and training datasets from the IEEE Signal Processing Cup (SPC). The proposed method provides the mean absolute error of 1.88 beats per minute (BPM) on all twenty-three recordings.

Conclusions: The proposed method uses the Fourier method in the fractional domain. A noisy signal is rotated into an intermediate plane between the time and frequency domains to separate the signal from the noise. The algorithm incorporates FrFT analysis to suppress motion artifacts from PPG signals to estimate HR accurately. Further, a post-processing step is used to track the HR for accurate and reliable HR estimation. The proposed FrFT-based algorithm doesn't require additional reference accelerometers or hardware to estimate HR in real-time. The noise and signal separation is optimum for a fractional order (a) value in the vicinity of 0.6. The optimized value of fractional order is constant irrespective of the physical activity and sampling frequency.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2022.107294DOI Listing

Publication Analysis

Top Keywords

motion artifacts
16
ppg signal
12
fractional order
12
proposed method
12
signal
8
heart rate
8
physical activity
8
fractional fourier
8
fourier transform
8
sampling frequency
8

Similar Publications

Background: Acute pain management is critical in postoperative care, especially in vulnerable patient populations that may be unable to self-report pain levels effectively. Current methods of pain assessment often rely on subjective patient reports or behavioral pain observation tools, which can lead to inconsistencies in pain management. Multimodal pain assessment, integrating physiological and behavioral data, presents an opportunity to create more objective and accurate pain measurement systems.

View Article and Find Full Text PDF

In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition.

View Article and Find Full Text PDF

Purpose: We investigated the feasibility and advantages of using non-contrast CT calcium score (CTCS) images to assess pericoronary adipose tissue (PCAT) and its association with major adverse cardiovascular events (MACE). PCAT features from coronary computed tomography angiography (CCTA) have been shown to be associated with cardiovascular risk but are potentially confounded by iodine. If PCAT in CTCS images can be similarly analyzed, it would avoid this issue and enable its inclusion in formal risk assessment from readily available, low-cost CTCS images.

View Article and Find Full Text PDF

Magnetic Resonance Imaging is a cornerstone of medical diagnostics, providing high-quality soft tissue contrast through non-invasive methods. However, MRI technology faces critical limitations in imaging speed and resolution. Prolonged scan times not only increase patient discomfort but also contribute to motion artifacts, further compromising image quality.

View Article and Find Full Text PDF

Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?