A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inhaled Epoprostenol and Milrinone Effect on Right Ventricular Pressure Waveform Monitoring. | LitMetric

Inhaled Epoprostenol and Milrinone Effect on Right Ventricular Pressure Waveform Monitoring.

Can J Cardiol

Department of Anesthesiology, Montreal Heart Institute, Université de Montréal, Montréal, Québec, Canada. Electronic address:

Published: April 2023

Background: Pulmonary hypertension (PH) and right ventricular (RV) dysfunction are major complications in cardiac surgery. This study aimed to evaluate the change in RV pressure waveform in patients receiving a combination of inhaled epoprostenol and inhaled milrinone (iE&iM) before cardiopulmonary bypass (CPB) and to assess the safety of this approach with a matched case-control group.

Methods: A prospective single-centre cohort study of adult patients undergoing cardiac surgery administered iE&iM through an ultrasonic mesh nebulizer. RV pressure waveform monitoring was obtained by continuously transducing the RV port of the pulmonary artery (PA) catheter.

Results: The final analysis included 26 patients receiving iE&iM. There was a significant drop in mean PA pressure (MPAP) (-4.8 ± 8.7, P = 0.010), systolic PA pressure (SPAP) (-8.2 ± 12.8, P = 0.003), RV end-diastolic pressure (RVEDP) (-2.1 ± 2.8, P < 0.001) and RV diastolic pressure gradient (RVDPG) (-1.7 ± 1.4, P < 0.001) after 17 ± 9 minutes of iE&iM administration. Patients also had a significant increase in RV outflow tract (RVOT) gradient (3.7 ± 4.7, P < 0.001), RV maximal rate of pressure rise during early systole (dP/dt max) (68.3 ± 144.7, P = 0.024), and left ventricular (LV) dP/dt max (66.4 ± 90.1, P < 0.001). Change in RVOT gradient was only observed in those with a positive pulmonary vasodilator response to treatment. Treatment with iE&iM did not present adverse effects when compared with a matched case-control group.

Conclusions: Coadministration of iE&iM in cardiac surgery patients presenting with PH or signs of RV dysfunction is a safe and effective treatment approach in improving RV function. Appearance of a transient increase in RVOT gradient after iE&iM could be useful to predict response to treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2022.12.007DOI Listing

Publication Analysis

Top Keywords

pressure waveform
12
cardiac surgery
12
rvot gradient
12
inhaled epoprostenol
8
pressure
8
waveform monitoring
8
patients receiving
8
matched case-control
8
dp/dt max
8
response treatment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!