Purpose: The comparison of bone ingrowth between two types of porous titanium alloy rods with different micro-architectures including diamond crystal lattice (Re-rod) and biogenic lamellar configurations (Bi-rod) on femoral condyles was investigated in this study.
Methods: Twelve rabbits were used. Re-rod (Re-rod group) and Bi-rod (Bi-rod group) were implanted randomly in femoral condyles of each rabbits respectively. Bone ingrowth of these two rods were investigated and compared. 4 and 12 weeks after the operation, X-ray, micro-CT and histological examinations were performed.
Results: No femoral condyle fracture and rod defluxion in the two groups was noted in the X-ray images during the observation period. Micro-CT images showed that all metal trabeculae in the Bi-rod group were covered by new bone at 4 and 12 weeks, whereas partial metal trabeculae in the Re-rod group were still uncovered at 12 weeks. Histological images showed that there was new bone growth in the centre and periphery of Bi-rods at 4 and 12 weeks, and there were several areas without new bone ingrowth at 4 and 12 weeks in the centre of Re-rods. In micro-CT analysis, the bone volume to total volume (BV/TV) of the volume of interest (VOI) of the Bi-rod group was higher than in the Re-rod group [(0.0794 ± 0.0021) % Vs (0.0521 ± 0.0032) % and (0.0875 ± 0.0039) % Vs (0.0702 ± 0.0028) % respectively, P < 0.05] at 4 weeks and 12 weeks. Whereas, the mean trabecular thickness (Tb.Th) values of VOI between the two groups were not significantly statistically different at 4 and 12 weeks. In histological analysis, the BV/TV of the VOI of the Bi-rod group was higher than in the Re-rod group [(0.0624 ± 0.0021) % Vs (0.0435 ± 0.0028) % and (0.0675 ± 0.0024) % Vs (0.0476 ± 0.0031) % respectively, P < 0.05] at 4 weeks and 12 weeks.
Conclusion: These results showed that Bi-rods got better bone ingrowth in femoral condyles of rabbits compared with Re-rods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bbrc.2022.12.036 | DOI Listing |
J Orthop Res
January 2025
Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA.
Patient-specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient-specific implant designed to address a superior-medial defect created in a standard pelvic geometry.
View Article and Find Full Text PDFCalcif Tissue Int
January 2025
Orthopaedic Research Laboratory, Department of Orthopedic Surgery and Traumatology, Odense University Hospital & Department of Clinical Research, University of Southern Denmark, V18-812B-1, Etage 1, Bygning 45.4, Nyt Sund, SDU Campus 5230, Odense, Denmark.
There is an increasing demand for a suitable bone substitute to replace current clinical gold standard autografts or allografts. Majority of previous studies have focused on the early effects of substitutes on bone formation, while information on their long-term efficacies remains limited. This study investigated the efficacies of natural hydroxyapatite (nHA) derived from oyster shells and synthetic hydroxyapatite mixed with collagen (COL/HA) or chitosan (CS/HA) on bone regeneration and implant fixation in sheep.
View Article and Find Full Text PDFBone Res
January 2025
The Guangdong Provincial Key Laboratory of Brain Connectome and Behavior, CAS Key Laboratory of Brain Connectome and Manipulation, the Brain Cognition and Brain Disease Institute (BCBDI), Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences; Shenzhen-Hong Kong Institute of Brain Science-Shenzhen Fundamental Research Institutions, Shenzhen, China.
Osteoarthritis (OA) is a degenerative joint disease accompanied with the loss of cartilage and consequent nociceptive symptoms. Normal articular cartilage maintains at aneural state. Neuron guidance factor Semaphorin 3A (Sema3A) is a membrane-associated secreted protein with chemorepulsive properties for axons.
View Article and Find Full Text PDFInt J Nanomedicine
December 2024
Department of Plastic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, People's Republic of China.
Purpose: Successful regeneration of cranial defects necessitates the use of porous bone fillers to facilitate cell proliferation and nutrient diffusion. Open porous microspheres, characterized by their high specific surface area and osteo-inductive properties, offer an optimal microenvironment for cell ingrowth and efficient ossification, potentially accelerating bone regeneration.
Materials And Methods: An in vitro investigation was conducted to assess the physicochemical properties, porosity, and biocompatibility of PHA-nano-clay open porous microspheres.
3D Print Addit Manuf
December 2024
Orthopedics Program, Herston Biofabrication Institute, Block 7 Royal Brisbane and Women's Hospital, Herston, Queensland, Australia.
The utilization of bone scaffold implants represents a promising approach for repairing substantial bone defects. In recent years, various traditional scaffold structures have been developed and, with advances in materials biology and computer technology, novel scaffold designs are now being evaluated. This study investigated the effects of a novel scaffold unit cell design (Hexanoid) through a computational framework, comparing its performance to that of four well-known scaffold designs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!