Purpose: To assess the accuracy of fit of complete-arch printed prosthesis prototypes generated with a digital workflow protocol for completely edentulous jaws.
Materials And Methods: Forty-five edentulous jaws (35 patients) underwent intraoral complete-arch digital scans with the double digital scanning (DDS) technique and the generated standard tessellation language (STL) files were superimposed and imported into computer-aided design software. After STL merging, each master STL file was used for printing a prosthesis prototype. The primary outcome was the accuracy of fit assessment of the printed prototypes on verified master stone casts. Two experienced clinicians tested the accuracy of fit with radiographs and screw-resistance tests. Secondary outcomes were the effect of the scan body shape and implant number on the accuracy of fit.
Results: Out of the 45 DDS-generated prosthesis prototypes, 39 presented with accurate fit on verified master stone casts, yielding an 86.70% accuracy of fit. Cylindrical scan bodies led to 100% accuracy of fit (25/25), whereas polygonal scan bodies presented with 70% accuracy of fit (14/20). Four implant-supported prostheses yielded 100% accuracy of fit (12/12), compared with 25/29 (86.30%) accuracy of fit for the six-implant-supported ones. Fisher's exact test was used to assess the effect of different scan body shapes (p = 0.005) and implant number on accuracy of fit. Chi-squared test was used to assess the association between the number of implants per arch and the accuracy of fit (p = 0.039).
Conclusions: Thirty-nine out of 45 complete-arch prosthesis prototypes generated with a completely digital workflow presented with clinically acceptable fit. The effect of the scan body design and implant number was statistically significant, favoring cylindrical scan bodies and four-implant-supported prostheses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jopr.13630 | DOI Listing |
Epilepsia Open
January 2025
Division of Pediatric Critical Care Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Objectives: Pediatric status epilepticus (SE) carries a high risk of morbidity and mortality and can result in neurologic injury. Establishing seizure activity on conventional EEG (cEEG) is essential but can delay treatment of seizures due to technician limitations. Rapid response EEG (rrEEG) device Ceribell and its Brain Stethoscope function can be used and interpreted rapidly by bedside providers with minimal training.
View Article and Find Full Text PDFCNS Neurosci Ther
January 2025
School of Information Science and Engineering, Lanzhou University, Lanzhou, China.
Aims: Drug-refractory epilepsy (DRE) refers to the failure of controlling seizures with adequate trials of two tolerated and appropriately chosen anti-seizure medications (ASMs). For patients with DRE, surgical intervention becomes the most effective and viable treatment, but its success rate is unsatisfactory at only approximately 50%. Predicting surgical outcomes in advance can provide additional guidance to clinicians.
View Article and Find Full Text PDFJ Clin Neurophysiol
January 2025
Department of Neurology, Washington University in St Louis, St. Louis, MO.
Purpose: Continuous EEG (cEEG) monitoring is increasingly used in the management of neonates with seizures. There remains debate on what clinically relevant information can be gained from cEEG in neonates with suspected seizures, at high risk for seizures, or with definite seizures, as well as the use of cEEG for prognosis in a variety of conditions. In this guideline, we address these questions using American Clinical Neurophysiology Society structured methodology for clinical guideline development.
View Article and Find Full Text PDFEndocr Relat Cancer
January 2025
M Stan, Endocrinology, Mayo Clinic, Rochester, 55905, United States.
Imaging-guided percutaneous core needle biopsy (PCNB) is currently the most common technique for the investigation of potentially malignant bone lesions. It allows precise needle placement and better visual guidance, leading to improved diagnostic accuracy. Needle tract seeding (NTS) is a rare complication of biopsies in general, and its true incidence remains unknown.
View Article and Find Full Text PDFJ Vis
January 2025
Department of Psychology, New York University, New York, NY, USA.
Active object recognition, fundamental to tasks like reading and driving, relies on the ability to make time-sensitive decisions. People exhibit a flexible tradeoff between speed and accuracy, a crucial human skill. However, current computational models struggle to incorporate time.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!