A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Frequency of errors in the transfer of treatment parameters from the treatment planning system to the oncology information system in a multi-vendor environment. | LitMetric

Background: Technological advancements have made it possible to improve patient outcomes in radiotherapy, sparing both normal tissues and increasing tumour control. However, these advancements have resulted in an increase in the number of software systems used, which each require data inputs to function. For institutions with multiple vendors for their treatment planning systems and oncology information systems, the transfer of data between them is potentially error prone and can lead to treatment errors.

Purpose: The goal of this work was to determine the frequency of errors in data transfers between the Varian Eclipse treatment planning system and the Elekta Mosaiq oncology information system.

Methods: An in-house program was used to quantify the number of errors for 2700 unique plans over an 8-month period. Using this information, the frequency of the errors were calculated. A risk priority number was calculated using the calculated frequencies to determine the impact on the clinic.

Results: The most common errors discovered were backup timer settings (10.7%), Field label (8.5%), DRR associations (3.3%), imaging field types (3.1%), dose rate (1%), Field Id (0.8%), imaging isocenter (0.7% and SSD (0.7%). Based on the risk priority numbers, the DRR association error was ranked as having the highest potential impact on the patient.

Conclusions: The results of the work show that the most effort should be focused on checking the manual steps performed in the transfer process, while items that are imported directly from DICOM-RT without modification are highly likely to be transferred accurately. The data can be used to help guide the implementation of future automated tools and process improvement in the clinic.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10113690PMC
http://dx.doi.org/10.1002/acm2.13868DOI Listing

Publication Analysis

Top Keywords

frequency errors
12
treatment planning
12
planning system
8
risk priority
8
treatment
5
errors transfer
4
transfer treatment
4
treatment parameters
4
parameters treatment
4
system oncology
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!