AI Article Synopsis

  • The study analyzes MRI turnaround times (TAT) for brain exams at four academic pediatric hospitals, highlighting a lack of comprehensive data on the topic across institutions.
  • Results show that TAT varies significantly, with sedated MRIs averaging 158 to 224 minutes, and non-sedated ones averaging 70 to 112 minutes, indicating a notable discrepancy from standard practice values.
  • Key factors affecting TAT include the type of MRI (sedated vs. non-sedated) and the specific hospital, emphasizing the need for improved consistency in pediatric practices.

Article Abstract

Background: Aside from single-center reports, few data exist across pediatric institutions that examine overall MRI turnaround time (TAT) and the determinants of variability.

Objective: To determine average duration and determinants of a brain MRI examination at academic pediatric institutions and compare the duration to those used in practice expense relative value units (RVUs).

Materials And Methods: This multi-institutional cross-sectional investigation comprised four academic pediatric hospitals. We included children ages 0 to < 18 years who underwent an outpatient MRI of the brain without contrast agent in 2019. Our outcome of interest was the overall MRI TAT derived by time stamps. We estimated determinants of overall TAT using an adjusted log-transformed multivariable linear regression model with robust standard errors.

Results: The average overall TAT significantly varied among the four hospitals. A sedated brain MRI ranged from 158 min to 224 min, a non-sedated MRI from 70 min to 112 min, and a limited MRI from 44 min to 70 min. The most significant predictor of a longer overall TAT was having a sedated MRI (coefficient = 0.71, 95% confidence interval [CI]: 0.66-0.75; P < 0.001). The median MRI scan time for a non-sedated exam was 38 min and for a sedated exam, 37 min, approximately double the duration used by the Relative Value Scale (RVS) Update Committee (RUC).

Conclusion: We found considerable differences in the overall TAT across four pediatric academic institutions. Overall, the significant predictors of turnaround times were hospital site and MRI pathway (non-sedated versus sedated versus limited MRI).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9758026PMC
http://dx.doi.org/10.1007/s00247-022-05563-9DOI Listing

Publication Analysis

Top Keywords

turnaround time
8
multi-institutional cross-sectional
8
pediatric institutions
8
academic pediatric
8
time efficiency
4
pediatric
4
efficiency pediatric
4
pediatric outpatient
4
outpatient brain
4
brain magnetic
4

Similar Publications

Pathology provides the definitive diagnosis, and Artificial Intelligence (AI) tools are poised to improve accuracy, inter-rater agreement, and turn-around time (TAT) of pathologists, leading to improved quality of care. A high value clinical application is the grading of Lymph Node Metastasis (LNM) which is used for breast cancer staging and guides treatment decisions. A challenge of implementing AI tools widely for LNM classification is domain shift, where Out-of-Distribution (OOD) data has a different distribution than the In-Distribution (ID) data used to train the model, resulting in a drop in performance in OOD data.

View Article and Find Full Text PDF

Evaluation of a Point-of-Care-Viscoelastic Coagulation Device in Hispaniolan Amazon Parrots ().

J Avian Med Surg

January 2025

Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA.

Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.

View Article and Find Full Text PDF

Acute promyelocytic leukemia (APL) accounts for approximately 10-15% of newly diagnosed acute myeloid leukemia cases and presents with coagulopathy and bleeding. Prompt diagnosis and treatment are required to minimize early mortality in APL as initiation of all-trans retinoic acid therapy rapidly reverses coagulopathy. The fusion is a hallmark of APL and its rapid identification is essential for rapid initiation of specific treatment to prevent early deaths from coagulopathy and bleeding and optimize patient outcomes.

View Article and Find Full Text PDF

Validation of glucose and lactate in cerebrospinal fluid (CSF) on a Radiometer blood gas analyzer ABL90 Flex plus.

Clin Biochem

January 2025

Pathology and Laboratory Medicine Program, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada; Memorial University of Newfoundland, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada. Electronic address:

Purpose: Rapid determination of cerebrospinal fluid (CSF) glucose and lactate is required by emergency rooms and intensive care units. Long turnaround time (TAT) on test results negatively impacts timely diagnosis and treatment of neurological infections like meningitis.

Methods: The CSF glucose and lactate assays were evaluated on a blood gas analyzer, Radiometer ABL90 Flex Plus.

View Article and Find Full Text PDF

Pathogen sequencing is an important tool for disease surveillance and demonstrated its high value during the COVID-19 pandemic. Viral sequencing during the pandemic allowed us to track disease spread, quickly identify new variants, and guide the development of vaccines. Tiled amplicon sequencing, in which a panel of primers is used for multiplex amplification of fragments across an entire genome, was the cornerstone of SARS-CoV-2 sequencing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!