Background: The amount of intra-articular displacement of the fracture is the main issue when deciding the treatment method between conservative or surgical means in intra-articular fractures. In this study, we aimed to determine the intraobserver and interobserver reliability of measuring intra-articular displacement and to compare the digital radiographic and computed tomographic (CT) evaluations in distal tibia intra-articular epiphyseal fractures.

Methods: Thirty-seven patients with digital radiography and CT scans were included in the study. Four sets were prepared with these images. Two of four sets were prepared as ankle radiographs, and the other two sets were prepared with CT scan views. Five observers were asked to measure the intra-articular displacement of the fractures in millimeters and also to make a decision between displacement amounts over or under 2 mm. Intraclass correlation coefficient scores were calculated for evaluation of intraobserver reliability, and Fleiss kappa values were calculated for interobserver reliability evaluations. A value greater than 0.75 was accepted as excellent agreement; 0.75 to 0.40 as intermediate to good agreement; and below 0.40 as poor agreement.

Results: There were 15 Salter-Harris type 3, 13 Salter-Harris type 4, seven triplanar, and two Tillaux-Chaput fractures. Both intraobserver and interobserver reliabilities were slightly higher for CT scan evaluations. Amounts of displacement were found to be measured higher after CT scan evaluations other than radiographs. After the measurement of joint displacements on CT scans, it was observed that the measurements found below 2 mm on the digital radiograph measurement changed to greater than or equal to 2 mm in 16.4% of the patients.

Conclusions: This study confirmed that digital radiographs cannot replace CT scans for the measurement of intra-articular displacement in ankle epiphyseal fractures.

Download full-text PDF

Source
http://dx.doi.org/10.7547/20-002DOI Listing

Publication Analysis

Top Keywords

intra-articular displacement
20
sets prepared
12
digital radiographs
8
displacement ankle
8
ankle epiphyseal
8
epiphyseal fractures
8
intraobserver interobserver
8
interobserver reliability
8
salter-harris type
8
higher scan
8

Similar Publications

Objective: To develop a clinical automated diagnostic system for temporomandibular disorders (TMD) based on the diagnostic criteria for TMD (DC/TMD) to assist dentists in making rapid and accurate clinical diagnosis of TMD.

Methods: Clinical and imaging data of 354 patients, who visited the Center for TMD & Orofacial Pain at Peking University Hospital of Stomatology from September 2023 to January 2024, were retrospectively collected. The study developed a clinical automated diagnostic system for TMD using the DC/TMD, built on the.

View Article and Find Full Text PDF

Proximal humeral fractures (PHF), ranking as the third most common osteoporotic fractures, pose a significant challenge in management. With a rising incidence in an aging population, controversy surrounds surgical versus nonoperative treatments, particularly for displaced 3- and 4-part fractures in older patients. Locking plates (LP) and proximal intramedullary nails (PHN) are primary choices for surgical intervention, but both methods entail complications.

View Article and Find Full Text PDF

Background And Objectives: Bennett fractures are intra-articular fractures of the first metacarpal, typically resulting from axial loading. The optimal surgical method for fixation remains a topic of ongoing debate. This study aims to evaluate and compare the biomechanical properties of different fixation techniques.

View Article and Find Full Text PDF

Objective: To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.

Methods: Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers.

View Article and Find Full Text PDF

Introduction: Olecranon fractures account for 5-7% of elbow fractures, making them a common injury. The majority of these fractures are treated surgically because they are intra-articular and can disrupt the elbow extensor mechanism. Mayo Type II fractures are displaced with a stable ulnohumeral joint, indicating intact ligamentous structures, particularly the anterior portion of the medial collateral ligament.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!