Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: The enhanced liver fibrosis (ELF) test is a noninvasive method for diagnosing hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD). This multicenter cohort study aimed to evaluate the accuracy of the ELF test and compare it with other noninvasive tests in Japan.
Methods: We analyzed 371 Japanese patients with biopsy-proven NAFLD. We constructed area under the receiver operator characteristic curves (AUROC) to determine the diagnostic accuracies of the ELF test, the Mac-2-binding protein glycosylation isomer (M2BPGi), the Fibrosis-4 (FIB-4) index, and combinations of these indices.
Results: In patients with F0/F1/F2/F3/F4 fibrosis, the median values of the ELF test were 8.98/9.56/10.39/10.92/11.41, respectively. The AUROCs of the ELF test for patients with F0 versus F1-4, F0-1 versus F2-4, F0-2 versus F3-4, and F0-3 versus F4 fibrosis were 0.825/0.817/0.802/0.812, respectively. The AUROCs of the ELF test were greater than those of the FIB-4 index and M2BPGi at each fibrosis stage. Respective low and high cut-off values yielded sensitivities and specificities for predicting advanced fibrosis (≥F3) of 91.1% and 50.8%, and 38.5% and 92.8%, respectively. For F3 or F4 fibrosis, the combined values from the ELF test and FIB-4 index showed a sensitivity of 98.5%, and the combined values from the ELF test and M2BPGi assay showed a specificity of 97.5%.
Conclusions: In Japan, the ELF test predicts NAFLD-related fibrosis from its early stages. The diagnostic ability of the ELF test was not inferior to that of other indices, and the combined values of ELF plus other indices were more accurate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/hepr.13871 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!