Background: Facing an increasing number of radiofrequency ablation (RF) and cryoballoon ablation (CB) procedures for treatment of AF radiation exposure and its reduction is a focus point for interventional electrophysiologists.

Objective: This study evaluated the procedural parameters of the different ablation methods focusing on radiation exposure and the BMI of the patients.

Methods: One thousand one hundred and thirty-three first procedural cases of pulmonary vein isolation in patients with paroxysmal and persistent AF treated with RF and CB-based techniques were analyzed retrospectively over a period of 7 years focusing on the endpoints dose area product (DAP, cGycm), fluoroscopy time (FT, min) and procedural time (PT, min).

Results: Of the 1133 patients (mean age 63.4 ± 11.4 years, BMI 28.9 ± 4.7) 335 patients received an RF procedure, 211 patients were treated with the cryoballoon first generation (CB1), and 587 patients with cryoballoon second generation (CB2), respectively. The mean DAP for the PVI was 508 ± 654 cGycm in RF procedures, 1077 ± 683 cGycm in CB1-procedures, and 587 ± 489 cGycm in CB2-procedures with fluoroscopy times significantly shorter in RF procedures (9.6 ± 5.2 min) as compared to 17.7 ± 5.9 min in CB1- and 16.3 ± 6.3 min in CB2-procedures ( < .001). At the same time, the procedure duration using RF (115 ± 33.5 min) was significantly longer than both in CB1 (96 ± 16.8 min) and CB2 procedures (75 ± 15.9 min).

Conclusions: Despite longer fluoroscopy durations in the CB technique, the CB2 resulted in a comparable low radiation exposure in PVI as compared to RF, accompanied by shorter procedure durations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9745457PMC
http://dx.doi.org/10.1002/joa3.12780DOI Listing

Publication Analysis

Top Keywords

radiofrequency ablation
8
radiation exposure
8
patients
5
x-ray exposure
4
cryoballoon
4
exposure cryoballoon
4
cryoballoon versus
4
versus radiofrequency
4
ablation
4
ablation atrial
4

Similar Publications

To assess the efficacy and safety of "one-stop" procedures combining radiofrequency catheter ablation and left atrial appendage closure by guidance of intracardiac echocardiography(ICE) in elderly patients with atrial fibrillation. A retrospective cohort study was conducted on patients who underwent ICE-guided "one-stop" procedures at the Department of Cardiology, General Hospital of Northern Theater Command between December 2020 and January 2023. Patients were divided into elderly group (age≥60 years old) and non-elderly group (age 18-59 years old).

View Article and Find Full Text PDF

Background: Junctional rhythm (JR) frequently occurs during radiofrequency (RF) ablation procedures targeting the slow pathway (SP) for atrioventricular nodal re-entrant tachycardia (AVNRT), signaling successful ablation. Two types of JR have been noticed: typical JR as His activation preceding atrial activation, and atypical JR as atrial activation preceding the His activation. Nevertheless, the origin and characteristics of JR remain incompletely defined.

View Article and Find Full Text PDF

Background & Aims: Radiofrequency ablation (RFA) is the standard treatment for small hepatocellular carcinoma (HCC), specifically for tumors <3 cm in size and numbering fewer than three, excluding surgical candidates. Microwave ablation (MWA) is an innovative approach believed to have theoretical benefits over RFA; however, these advantages are yet to be empirically verified. Therefore, we evaluated and compared the effectiveness of MWA and RFA in managing HCC tumors up to 4 cm in size.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!