A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility of Intraoperative Visual Evoked Potential Monitoring by Cortical Strip Electrodes in Patients During Brain Surgery: A Preliminary Study. | LitMetric

Objective: The role of visual evoked potentials (VEPs) monitoring during neurosurgical procedure in patient remains unclear. The purpose of our study was to determine the feasibility of intraoperative VEP recording using a strip cortical electrode during surgical resection of intracranial lesions.

Methods: In this prospective, monocentric, observational study, we enrolled consecutive patients undergoing neurosurgical procedure for intracranial lesions. After dural opening, a cortical strip was positioned on the lateral occipital surface. Flash VEPs were continuously recorded using both subdermal corkscrew electrodes and strip electrodes. An electroretinogram was also recorded to guarantee delivery of adequate flash stimuli to the retina.

Results: We included 10 patients affected by different intracranial lesions. Flash VEPs were recorded using subdermal corkscrew electrodes in all patients except 1 in whom they were never identified during the recording. Flash VEPs were recorded using strip electrodes in all patients and showed a polyphasic morphology with a significantly larger amplitude compared with that of flash VEPs measured using subdermal corkscrew electrodes. No patient reported worsened postoperative vision and a >50% decrease in the VEPs amplitude was never registered.

Conclusions: We have reported for the first time in the literature that VEP monitoring during a neurosurgical procedure is feasible via a cortical strip located on the occipital surface. The technique demonstrated greater stability and a larger amplitude compared with recordings with scalp electrodes, facilitating identification of any changes. Studies with more patients are needed to assess the clinical reliability of the technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2022.12.032DOI Listing

Publication Analysis

Top Keywords

flash veps
16
cortical strip
12
strip electrodes
12
electrodes patients
12
neurosurgical procedure
12
subdermal corkscrew
12
corkscrew electrodes
12
feasibility intraoperative
8
visual evoked
8
monitoring neurosurgical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!