Supraphysiological loading induced by unstable orthopedic implants initiates osteoclast formation, which results in bone degradation. We aimed to investigate which mechanosensitive cells in the peri-implant environment produce osteoclast-stimulating factors and how the production of these factors is stimulated by supraphysiological loading. The release of osteoclast-stimulating factors by different types of isolated bone marrow-derived hematopoietic and mesenchymal stem cells from six osteoarthritic patients was analyzed after one hour of supraphysiological loading (3.0 ± 0.2 Pa, 1 Hz) by adding their conditioned medium to osteoclast precursors. Monocytes produced factors that enhanced osteoclastogenesis by 1.6 ± 0.07-fold and mesenchymal stem cells by 1.4 ± 0.07-fold. Medium from osteoprogenitors and pre-osteoblasts enhanced osteoclastogenesis by 1.3 ± 0.09-fold and 1.4 ± 0.03-fold, respectively, where medium from four patients elicited a response and two did not. Next generation sequencing analysis of osteoprogenitors revealed that genes encoding for inflammation-related pathways and cytoskeletal rearrangements were regulated differently between responders and non-responders. Our data suggest that released osteoclast-stimulating soluble factors by progenitor cells in the bone marrow after supraphysiological loading may be related to cytoskeletal arrangement in an inflammatory environment. This connection could be relevant to better understand the aseptic loosening process of orthopedic implants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9751069PMC
http://dx.doi.org/10.1038/s41598-022-25567-7DOI Listing

Publication Analysis

Top Keywords

supraphysiological loading
20
osteoclast-stimulating factors
12
release osteoclast-stimulating
8
cytoskeletal arrangement
8
orthopedic implants
8
stem cells
8
enhanced osteoclastogenesis
8
factors
6
supraphysiological
5
loading
5

Similar Publications

Although left ventricular assist devices (LVADs) are an alternative to heart transplantation, their artificial surfaces often lead to serious thrombotic complications requiring high-risk device replacement. Coating blood-contacting surfaces with antithrombogenic endothelial cells is considered an effective strategy for preventing thrombus formation. However, this concept has not yet been successfully implemented in LVADs, as severe cell loss is to be expected, especially on the impeller surface with high prothrombogenic supraphysiological shear stress.

View Article and Find Full Text PDF

During intravascular procedures, medical devices interact mechanically with vascular tissue. The device design faces a trade-off: although a high bending stiffness improves its maneuvrability and deliverability, it may also trigger excessive supra-physiological loading that may result in tissue damage. In particular, the collagen fibers in vascular walls are load-bearing but may rupture on a microscopic scale due to mechanical interaction.

View Article and Find Full Text PDF

Background: Major histocompatibility complex class-1-related protein (MR1), unlike human leukocyte antigen (HLA) class-1, was until recently considered to be monomorphic. MR1 presents metabolites in the context of host responses to bacterial infection. MR1-restricted TCRs specific to tumor cells have been described, raising interest in their potential therapeutic application for cancer treatment.

View Article and Find Full Text PDF

L-carnitine for valproic acid-induced toxicity.

Br J Clin Pharmacol

September 2024

National Poisons Information Service (Newcastle unit), Newcastle-upon-Tyne Hospitals NHS Foundation Trust, UK.

Aims: Review the effectiveness and dosing of L-carnitine for valproic-acid induced toxicity.

Methods: A literature review of the pharmacokinetics and clinical use of L-carnitine was performed.

Results: Valproic acid is a fatty acid used for numerous therapeutic indications ranging from epilepsy to bipolar disorder.

View Article and Find Full Text PDF
Article Synopsis
  • Catastrophic cervical spine injuries in rugby often happen during tackles, but the exact causes are not fully understood, with neck hyperflexion and buckling being suggested factors.
  • This study explored how the position of a player’s head and neck before impact affects the forces and movements in the neck during a head-first tackle, using a detailed computer simulation model of a rugby player.
  • Results showed that an extended neck position can lead to dangerous loads that might cause serious injuries, while a flexed neck position does not exceed safe limits, providing insights for improving safety in rugby through injury prevention strategies or rule changes.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!